Abstract
His-bundle electrocardiogram micropotentials are usually obtained by serial-signal averaging, because no acceptable, satisfactory solution for beat-by-beat removal of power-line interference and electromyographic noise has been found. A method has been developed for surface beat-to-beat His-bundle potential recovery, with the hypothesis that no distortion in the signal shape is admissible. It is based on consecutive power-line interference subtraction and wavelet-domain electromyographic noise suppression, modified to match the strict criteria for detecting low-amplitude His potentials. The beat-to-beat wavelet-domain Wiener filtering uses a pilot signal estimate obtained from a limited number (around 20) of heart beat averages. The method resulted in an improvement of more than 4.5 dB in the signal-to-noise ratio and more than 20% reduction in mean absolute error, both measured along the P-Q segment. It is applicable for ECG signals contaminated by moderate electromyogram noise, with an initial signal-to-noise ratio of 15 dB or higher.
Similar content being viewed by others
References
Bazhyna, A., Christov, I. I., Gotchev, A., Daskalov, I. K., andEgiazarian, K. (2003): ‘Power-line interference suppression in high-resolution ECG’,Comput. Cardiol.,30, pp. 561–564
Bensadoun, Y., Novakov, E., Raoof, K., andDefaye, P. (1997): ‘Beat-to-beat detection of ventricular late potentials and His potential using the adaptive orthogonal projection’. Proc. 19th Int. Conf. Eng. in Med. & Biology, IEEE/EMBS, Chicago, USA,1, pp. 81–84
Choi, H., andBaraniuk, R. (1998): ‘Analysis of wavelet-domain Wiener filters’. Proc. IEEE-SP Int. Symp. Time-frequency and Time-scale Analysis, Pittsburgh, Pennsylvania, USA, October 1998, pp. 613–616
Christov, I., andDotsinsky, I. (1988): ‘New approach to the digital elimination of 50 Hz interference from the electrocardiogram’,Med. Biol. Eng. Comput.,26, pp. 431–434
Christov, I., andDaskalov, I. (1999): ‘Filtering of electrocardiogram artifacts from the electrocardiogram’,Med. Eng. Phys.,21, pp. 731–736
Christov, I. (2000): ‘Dynamic power-line interference subtraction from biosignals’,J. Med. Eng. Tech.,24, pp. 169–172
Daskalov, I. K., Dotsinsky, I. A., andChristov, I. I. (1998): ‘Developments in ECG acquisition, preprocessing, parameter measurement and recording’,IEEE Eng. Med. Biol.,17, pp. 50–58
Donoho, D., andJohnstone, I. (1995): ‘Adapting to unknown smoothness via wavelet shrinkage’,J. Am. Stat. Assoc.,90, pp. 1200–1224
Dotsinsky, I., andStoyanov, T. (2002): ‘Cancellation of the powerline interference: effect of amplitude and frequency variations on the ECG signal’. Proc. 11th Int. Conf. ‘Electronics-ET'2002’, Sozopol, Bulgaria, pp. 65–70
Flowers, N., Shvartsman, V., Kennelly, B., Sohi, G., andHoran, L. (1981): ‘Surface recording of His-Purkinje activity on an every-beat basis without digital averaging’,Circulation,63, pp. 948–952
Ghael, S., Sayeed, A., andBaraniuk, R. (1997): ‘Improved wavelet de noising via empirical Wiener filtering’,Proc. SPIE,3169, pp. 389–399
Gotchev, A., Christov, I., andEgiazarian, K. (2002): ‘Denoising the electrocardiogram from electromyogram artifacts by combined transform-domain and dynamic approximation method’. Proc. Int. Conf. Acoustics, Speech & Signal Processing, ICASSP'2002, Orlando, USA, pp. 3872–3875
Jain, A. (1989): ‘Fundamentals of digital image processing’ (Prentice-Hall, 1989).
Levkov, C., Michov, G., Ivanov, R., andDaskalov, I. (1984): ‘Subtraction of 50 Hz interference from the electrocardiogram’,Med. Biol. Eng. Comput.,22, pp. 371–373
Mallat, S. (1999): ‘A wavelet tour of signal processing’ (Academic Press, 1999)
Moon, T., andStirling, W. (2000): ‘Mathematical methods and algorithms for signal processing’ (Prentice-Hall, 2000)
Nikolaev, N., andGotchev, A. (2000): ‘ECG signal denoising using wavelet domain Wiener filtering’. Proc. European Signal Processing Conf. EUSIPCO-2000, Tampere, Finland, pp. 51–54.
Nikolaev, N., Nikolov, Z., Gotchev, A., andEgiazarian, K. (2000): ‘Wavelet domain Wiener filtering for ECG denoising using an improved signal estimate’. Proc. Int. Conf. Acoustics, Speech & Signal Processing, ICASSP'2000, Istanbul, Turkey, pp. 2210–2213
Nikolaev, N., Gotchev, A., Egiazarian, K., andNikolov, Z. (2001): ‘Suppression of electromyogram interference on the electrocardiogram by transform domain denoising’,Med. Biol. Eng. Comput.,39, pp. 649–655
Pei, S.-C., andTseng, C.-C. (1995): ‘Elimination of AC interference in electrocardiogram using IIR notch filter with transient suppression’,IEEE Trans. Biomed. Eng.,42, pp. 1128–1132
Peper, A., Jonges, R., Grimberger, C. A., Losekoot, T. G., andStrackee, J. (1990): ‘Method for the computation of an accurate zero reference for ECG signals’,Med. Biol. Eng. Comput.,28, pp. 105–112
Proakis, J., Rader, C., Ling, F., Nikias, C., Moonen, M., andProudler, I. (2002): ‘Algorithms for statistical signal processing’ (Prentice-Hall, 2002)
Sherlag, B., Lau, S., Helfant, R., Berkowitz, W., Stein, E., andDamato, A. (1969): ‘Catheter technique for recording His-bundle activity in man’,Circulation,39, pp. 13–18
Turner, I., Wang, W., English, M., andVincent, R. (1995): ‘Noise coherence in closely-spaced electrodes: the implications for spatial averaged ECG recordings’,J. Med. Eng. Technol.,19, pp. 158–161
Veterli, M., andKovacevic, J. (1995): ‘Wavelets and subband coding’ (Prentice-Hall, New York, 1995)
Wagner, G. S. (2001): ‘Marriott's practical electrocardiography’ inWilliams andWilkins, (Eds): (Lippincott, Williams & Wilkins, Philadelphia, Baltimore, New York, London, Buenos Aires, Hong Kong, Sydney, Tokyo), 10th edn.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bazhyna, A., Gotchev, A., Christov, I.I. et al. Beat-to-beat noise removal in noninvasive His-bundle electrocardiogram. Med. Biol. Eng. Comput. 42, 712–719 (2004). https://doi.org/10.1007/BF02347555
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02347555