Skip to main content
Log in

Beat-to-beat noise removal in noninvasive His-bundle electrocardiogram

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

His-bundle electrocardiogram micropotentials are usually obtained by serial-signal averaging, because no acceptable, satisfactory solution for beat-by-beat removal of power-line interference and electromyographic noise has been found. A method has been developed for surface beat-to-beat His-bundle potential recovery, with the hypothesis that no distortion in the signal shape is admissible. It is based on consecutive power-line interference subtraction and wavelet-domain electromyographic noise suppression, modified to match the strict criteria for detecting low-amplitude His potentials. The beat-to-beat wavelet-domain Wiener filtering uses a pilot signal estimate obtained from a limited number (around 20) of heart beat averages. The method resulted in an improvement of more than 4.5 dB in the signal-to-noise ratio and more than 20% reduction in mean absolute error, both measured along the P-Q segment. It is applicable for ECG signals contaminated by moderate electromyogram noise, with an initial signal-to-noise ratio of 15 dB or higher.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bazhyna, A., Christov, I. I., Gotchev, A., Daskalov, I. K., andEgiazarian, K. (2003): ‘Power-line interference suppression in high-resolution ECG’,Comput. Cardiol.,30, pp. 561–564

    Google Scholar 

  • Bensadoun, Y., Novakov, E., Raoof, K., andDefaye, P. (1997): ‘Beat-to-beat detection of ventricular late potentials and His potential using the adaptive orthogonal projection’. Proc. 19th Int. Conf. Eng. in Med. & Biology, IEEE/EMBS, Chicago, USA,1, pp. 81–84

  • Choi, H., andBaraniuk, R. (1998): ‘Analysis of wavelet-domain Wiener filters’. Proc. IEEE-SP Int. Symp. Time-frequency and Time-scale Analysis, Pittsburgh, Pennsylvania, USA, October 1998, pp. 613–616

  • Christov, I., andDotsinsky, I. (1988): ‘New approach to the digital elimination of 50 Hz interference from the electrocardiogram’,Med. Biol. Eng. Comput.,26, pp. 431–434

    Google Scholar 

  • Christov, I., andDaskalov, I. (1999): ‘Filtering of electrocardiogram artifacts from the electrocardiogram’,Med. Eng. Phys.,21, pp. 731–736

    Article  Google Scholar 

  • Christov, I. (2000): ‘Dynamic power-line interference subtraction from biosignals’,J. Med. Eng. Tech.,24, pp. 169–172

    Article  Google Scholar 

  • Daskalov, I. K., Dotsinsky, I. A., andChristov, I. I. (1998): ‘Developments in ECG acquisition, preprocessing, parameter measurement and recording’,IEEE Eng. Med. Biol.,17, pp. 50–58

    Google Scholar 

  • Donoho, D., andJohnstone, I. (1995): ‘Adapting to unknown smoothness via wavelet shrinkage’,J. Am. Stat. Assoc.,90, pp. 1200–1224

    MathSciNet  Google Scholar 

  • Dotsinsky, I., andStoyanov, T. (2002): ‘Cancellation of the powerline interference: effect of amplitude and frequency variations on the ECG signal’. Proc. 11th Int. Conf. ‘Electronics-ET'2002’, Sozopol, Bulgaria, pp. 65–70

  • Flowers, N., Shvartsman, V., Kennelly, B., Sohi, G., andHoran, L. (1981): ‘Surface recording of His-Purkinje activity on an every-beat basis without digital averaging’,Circulation,63, pp. 948–952

    Google Scholar 

  • Ghael, S., Sayeed, A., andBaraniuk, R. (1997): ‘Improved wavelet de noising via empirical Wiener filtering’,Proc. SPIE,3169, pp. 389–399

    Google Scholar 

  • Gotchev, A., Christov, I., andEgiazarian, K. (2002): ‘Denoising the electrocardiogram from electromyogram artifacts by combined transform-domain and dynamic approximation method’. Proc. Int. Conf. Acoustics, Speech & Signal Processing, ICASSP'2002, Orlando, USA, pp. 3872–3875

  • Jain, A. (1989): ‘Fundamentals of digital image processing’ (Prentice-Hall, 1989).

  • Levkov, C., Michov, G., Ivanov, R., andDaskalov, I. (1984): ‘Subtraction of 50 Hz interference from the electrocardiogram’,Med. Biol. Eng. Comput.,22, pp. 371–373

    Google Scholar 

  • Mallat, S. (1999): ‘A wavelet tour of signal processing’ (Academic Press, 1999)

  • Moon, T., andStirling, W. (2000): ‘Mathematical methods and algorithms for signal processing’ (Prentice-Hall, 2000)

  • Nikolaev, N., andGotchev, A. (2000): ‘ECG signal denoising using wavelet domain Wiener filtering’. Proc. European Signal Processing Conf. EUSIPCO-2000, Tampere, Finland, pp. 51–54.

  • Nikolaev, N., Nikolov, Z., Gotchev, A., andEgiazarian, K. (2000): ‘Wavelet domain Wiener filtering for ECG denoising using an improved signal estimate’. Proc. Int. Conf. Acoustics, Speech & Signal Processing, ICASSP'2000, Istanbul, Turkey, pp. 2210–2213

  • Nikolaev, N., Gotchev, A., Egiazarian, K., andNikolov, Z. (2001): ‘Suppression of electromyogram interference on the electrocardiogram by transform domain denoising’,Med. Biol. Eng. Comput.,39, pp. 649–655

    Article  Google Scholar 

  • Pei, S.-C., andTseng, C.-C. (1995): ‘Elimination of AC interference in electrocardiogram using IIR notch filter with transient suppression’,IEEE Trans. Biomed. Eng.,42, pp. 1128–1132

    Google Scholar 

  • Peper, A., Jonges, R., Grimberger, C. A., Losekoot, T. G., andStrackee, J. (1990): ‘Method for the computation of an accurate zero reference for ECG signals’,Med. Biol. Eng. Comput.,28, pp. 105–112

    Google Scholar 

  • Proakis, J., Rader, C., Ling, F., Nikias, C., Moonen, M., andProudler, I. (2002): ‘Algorithms for statistical signal processing’ (Prentice-Hall, 2002)

  • Sherlag, B., Lau, S., Helfant, R., Berkowitz, W., Stein, E., andDamato, A. (1969): ‘Catheter technique for recording His-bundle activity in man’,Circulation,39, pp. 13–18

    Google Scholar 

  • Turner, I., Wang, W., English, M., andVincent, R. (1995): ‘Noise coherence in closely-spaced electrodes: the implications for spatial averaged ECG recordings’,J. Med. Eng. Technol.,19, pp. 158–161

    Google Scholar 

  • Veterli, M., andKovacevic, J. (1995): ‘Wavelets and subband coding’ (Prentice-Hall, New York, 1995)

    Google Scholar 

  • Wagner, G. S. (2001): ‘Marriott's practical electrocardiography’ inWilliams andWilkins, (Eds): (Lippincott, Williams & Wilkins, Philadelphia, Baltimore, New York, London, Buenos Aires, Hong Kong, Sydney, Tokyo), 10th edn.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. Gotchev.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bazhyna, A., Gotchev, A., Christov, I.I. et al. Beat-to-beat noise removal in noninvasive His-bundle electrocardiogram. Med. Biol. Eng. Comput. 42, 712–719 (2004). https://doi.org/10.1007/BF02347555

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02347555

Keywords

Navigation