Skip to main content
Log in

Computerised audiovisual event recording for infant apnoea and bradycardia

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Event recording, by differentiating between true and false events, has advanced the diagnosis and management of infants on home cardiorespiratory monitors; however, the pathogenesis of many events remains obscure. To clarify infant behaviours around the time of apnoea/bradycardia alarms, a computerised audiovisual event recording system (CAVERS) triggered by the apnoea/bradycardia recorder, has been developed. The audiovisual recording can begin up to 3 min before the alarm and can continue for up to 3 min after the alarm. CAVERS information is recorded for a total of 65 events in 13 infants. The CAVERS proves most helpful in documenting infant position and the wide variety of behaviours associated with bradycardic events. These behaviours range from sleep or quiet wakefulness to crying and generalised movements. Post-event activity is also highly variable. Interestingly, 20 of 65 events appear to terminate when the infant wakes to the audible monitor alarm. Nursing intervention is documented for 14 of 42 bradycardic events but only one of 23 apnoeic events. The CAVERS, by elucidating infant behaviours, provides information complementary to that given by cardiorespiratory event recording. It is suggested that infant monitors of the future should incorporate both audiovisual and cardiorespiratory data to elucidate optimally apparent life-threatening events, apnoeas and bradycardias.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Apnea Monitoring Committee (1989): ‘Apnea monitoring by means of thoracic impedance pneumography’ (Association for the Advancement of Medical Instrumentation, Arlington, Virginia)

    Google Scholar 

  • Anders, T. F. (1976): ‘The use of time lapse video recording of sleep-wake behavior in human infants’,Psychophysiology,13, pp. 155–158

    Google Scholar 

  • Barker, S. J., andShah, N. K. (1997): ‘The effects of motion on the performance of pulse oximeters in volunteers (revised publication)’,Anesthesiology,86, pp. 101–108

    Google Scholar 

  • Brooks, J. G. (1992): ‘Apparent life-threatening events and apnea of infancy’,Clin. Perinatol.,19, pp. 809–838

    Google Scholar 

  • Chiodini, B. A., andThach, B. T. (1993): ‘Impaired ventilation in infants sleeping facedown: potential significance for sudden infant death syndrome’,J. Pediatr.,123, pp. 686–692

    Google Scholar 

  • Cote, A., Hum, C., Brouillette, R. T., andThemens, M. (1998): ‘Frequency and timing of recurrent events in infants using home cardiorespiratory monitors’,J. Pediatr.,132, pp. 783–789

    Google Scholar 

  • de Broca, A., Zenatti, I., Dorival, D., Kremp, O., Faltaous, S., andRisbourg, B. (1992): ‘Surveillance cardiorespiratoire a domicile avec alarmes enregistrees chez des nourrissons a risque de malaises’,Pediatrie. (Bucur.),47, pp. 59–65

    Google Scholar 

  • Erlichman, M. (1990): ‘Electroencephalographic (EEG) video monitoring’,Health Technol. Asses. Rep.,4, pp. 1–14

    Google Scholar 

  • Fleming, P. J., Blair, P. S., Bacon, C., Bensley, D., Smith, I., Taylor, E., Berry, J., Golding, J., andTripp, J. (1996): ‘Environment of infants during sleep and risk of the sudden infant death syndrome: results of 1993-5 case-control study for confidential inquiry into stillbirths and deaths in infancy. Confidential Enquiry into Stillbirths and Deaths Regional Coordinators and Researchers’,Br. Med. J.,313, pp. 191–195

    Google Scholar 

  • Krongrad, E., andO'Neill, L. (1986): ‘Near miss sudden infant death syndrome episodes? A clinical and electrocardiographic correlation’,Pediatrics,77, pp. 811–815

    Google Scholar 

  • Little, G. A., Ballard, R. A., Brooks, J. G., Brouillette, R. T., Cullpepper, L., Gray, H. B., King, P., Kolb, M. O., Neale, A., Neuman, M. R., Peterson, D. R., Schweitzer, S. O., andWeiss, H. (1987): ‘National Institutes of Health Consensus Development Conference on infantile apnea and home monitoring’, 29 Sept-1 Oct., 1986,Pediatrics,79, pp. 292–299

    Google Scholar 

  • Marcus, C. L., andHamer, A. (1999): ‘Significance of isolated bradycardia detected by home monitoring’,J. Pediatr.,135, pp. 321–326

    Google Scholar 

  • Meny, R. G., Carroll, J. L., Carbone, M. T., andKelly, D. H. (1994): ‘Cardiorespiratory recordings from infants dying suddenly and unexpectedly at home’,Pediatrics,93, pp. 44–49

    Google Scholar 

  • Morielli, A., Ladan, S., Ducharme, F. M., andBrouillette, R. T. (1996): ‘Can sleep and wakefulness be distinguished in children by cardiorespiratory and videotape recordings?’,Chest,109, pp. 680–687

    Google Scholar 

  • Muttitt, S. C., Finer, N. N., Tierney, A. J., andRossmann, J. (1988): ‘Neonatal apnea: diagnosis by nurse versus computer’.Pediatrics,82, pp. 713–720

    Google Scholar 

  • Nathanson, I., O'Donnell, J., andCommins, M. F. (1989): ‘Cardlorespiratory patterns during alarms in infants using apnea/bradycadia monitors’,Am. J. Dis. Child,143, pp. 476–480

    Google Scholar 

  • Poets, C. F., Samuels, M. P., Noyes, J. P., Hewertson, J., Hartmann, H., Holder, A., andSouthall, D. P. (1993): ‘Home event recordings of oxygenation, breathing movements, and heart rate and rhythm in infants with recurrent life-threatening events’,J. Pediatr.,123, pp. 693–701

    Google Scholar 

  • Poets, C. F., Meny, R. G., Chobanian, M. R., andBonofiglo, R. E. (1999): ‘Gasping and other cardiorespiratory patterns during sudden infant deaths’,Pediatr. Res.,45, pp. 350–354

    Google Scholar 

  • Samuels, M. P., Poets, C. F., andSouthall, D. P. (1994): ‘Abnormal hypoxemia after life-threatening events in infants born before term’,J. Pediatr.,125, pp. 441–446

    Google Scholar 

  • Samuels, M. P., andSouthall, D. P. (1994): ‘Video surveillance in diagnosis of intentional suffocation’,Lancet,344, p. 414

    Article  Google Scholar 

  • Scheers, N. J., Dayton, C. M., andKemp, J. S. (1998): ‘Sudden infant death with external airways covered: case-comparison study of 206 deaths in the United States’,Arch. Pediatr. Adolesc. Med.,152, pp. 540–547

    Google Scholar 

  • Silvestri, J. M., Hufford, D. R. J., Durham, J., Pearsall, S. M., Gess, M. A., Weese-Mayer, D. E., Hunt, C. E., Levenson, S. M., andCorwin, M. J. (1995): ‘Assessment of compliance with home cardiorespiratory monitoring in infants at risk of sudden infant death syndrome’, Collaborative home infant monitoring evaluation (CHIME),J. Pediatr.,127, pp. 384–388

    Google Scholar 

  • Southall, D. P., Levitt, G. A., Richards, J. M., Jones, R. A., Kong, C., Farndon, P. A., Alexander, J. R., andWilson, A. J. (1983): ‘Undetected episodes of prolonged apnea and severe bradycardia in preterm infants’,Pediatrics,72, pp. 541–551

    Google Scholar 

  • Southall, D. P., Plunkett, M. C., Banks, M. W., Falkov, A. F., andSamuels, M. P. (1997): ‘Covert video recordings of life-threatening child abuse: lessons for child protection’,Pediatrics,100, pp. 735–760

    Article  Google Scholar 

  • Steinschneider, A., andSantos, V. (1991): ‘Parental reports of apnea and bradycardia: temporal characteristics and accuracy’,Pediatrics,88, pp. 1100–1105

    Google Scholar 

  • Sundaram, M., Sadler, R. M., Young, G. B., andPillay, N. (1999): ‘EEG in epilepsy: current perspectives’,Can. J. Neurol. Sci.,26, pp. 255–262

    Google Scholar 

  • Waters, K. A., Gonzalez, A., Jean, C., Morielli, A., andBrouillette, R. T. (1996): ‘Face-straight-down and face-near-straight-down positions in healthy, prone-sleeping infants’,J. Pediatr.,128, pp. 616–625

    Google Scholar 

  • Weese-Mayer, D. E., Brouillette, R. T., Morrow, A. S., Conway, L. P., Klemka-Walden, L. M., andHunt, C. E. (1989): ‘Assessing validity of infant monitor alarms with event recording’,J. Pediatr.,115, pp. 702–708

    Google Scholar 

  • Weese-Mayer, D. E., Morrow, A. S., Conway, L. P., Brouillette, R. T., andSilvestri, J. M. (1990): ‘Assessing clinical significance of apnea exceeding fifteen seconds with event recording’,J. Pediatr.,117, pp. 568–574

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. T. Brouillette.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Brouillette, R.T., Tsirigotis, D., Leimanis, A. et al. Computerised audiovisual event recording for infant apnoea and bradycardia. Med. Biol. Eng. Comput. 38, 477–482 (2000). https://doi.org/10.1007/BF02345740

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02345740

Keywords

Navigation