Medical and Biological Engineering and Computing

, Volume 41, Issue 5, pp 516–518 | Cite as

Some technical aspects of magnetic stimulation coil design with the ferromagnetic effect

  • B. H. Han
  • S. Y. Lee
  • J. H. Kim
  • J. H. Yi
Technical Note

Abstract

The performance of the stimulation coil in a magnetic nerve stimulator can be improved by attaching a ferromagnetic structure to the coil. This reduces heat generation at the coil and increases magnetic field strength for a given unit of current. Some technical aspects of the design of a stimulation coil with a ferromagnetic structure have been studied. Finite element method analysis results are presented for the effect of size, depth and magnetic saturation of the ferromagnetic structure on the stimulation coil performance. The experimental results show that the stimulation coil performance is improved by up to 40% by the attaching of a ferromagnetic structure on the coil.

Keywords

Magnetic nerve stimulation Ferromagnetic effect Stimulation coil Coil efficiency 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Davey, K. R., Cheng, C. H., andEpstein, C. M. (1991): ‘Prediction of magnetically induced electric fields in biological tissue’,IEEE Trans. Biomed. Eng.,38, pp. 418–422CrossRefGoogle Scholar
  2. Davey, K., andEpstein, C. M. (2000): ‘Magnetic stimulation coil and circuit design’,IEEE Trans. Biomed. Eng.,47, pp. 1493–1499CrossRefGoogle Scholar
  3. Grandori, F., andRavazzani, P. (1991): ‘Magnetic stimulation of the motor cortex—theoretical considerations’,IEEE Trans. Biomed. Eng.,38, pp. 180–191CrossRefGoogle Scholar
  4. Ishikawa, N., Suda, S., Sasaki, T., Yamanishi, T., Hosaka, H., Yasuda, K., andIto, H. (1998): ‘Development of a non-invasive treatment system for urinary incontinence using a functional continuous magnetic stimulator’,Med. Biol. Eng. Comput.,36, pp. 704–710Google Scholar
  5. Jalinous, R. (1991): ‘Technical and practical aspects of magnetic nerve stimulation’,J. Clin. Neurophysiol.,8, pp. 10–25Google Scholar
  6. Moon, C. H., Park, H. W., andLee, S. Y. (1999): ‘A design method for minimum-inductance planar magnetic-resonance-imaging gradient coils considering the pole-piece effect’,Meas. Sci. Technol.,10, pp. N136-N141CrossRefGoogle Scholar
  7. Polson, N. J. R., Barker, A. T., andGardiner, S. (1982): ‘Stimulation of nerve trunks with time-varying magnetic fields’,Med. Biol. Eng. Comput.,20, pp. 243–244Google Scholar
  8. Roth, B. J., andBasser, P. J. (1991): ‘A model of the stimulation of a nerve fiber by electromagnetic induction’,IEEE Trans. Biomed. Eng.,37, pp. 588–597Google Scholar
  9. Ruohonen, J., andIlmoniemi, R. J. (1998): ‘Focusing and targeting of magnetic brain stimulation using multiple coils’,Med. Biol. Eng. Comput.,36, pp. 297–301Google Scholar
  10. Ruohonen, J., Ravazzani, P., Grandori, F., andIlmoniemi, R. (1999): ‘Theory of multichannel magnetic stimulation: toward functional neuromuscular rehabilitation’,IEEE Trans. Biomed. Eng.,46, pp. 646–651CrossRefGoogle Scholar

Copyright information

© IFMBE 2003

Authors and Affiliations

  1. 1.Graduate School of East-West Medical ScienceKyung Hee UniversityKorea
  2. 2.Department of Biomedical EngineeringHanyang UniversityKorea
  3. 3.Department of Biomedical EngineeringKonkuk UniversityKorea

Personalised recommendations