Skip to main content
Log in

Computerised analysis of auscultatory sounds associated with vascular patency of haemodialysis access

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Vascular access for renal dialysis is a lifeline for about 120 000 individuals in the United States. Stethoscope auscultation of vascular sounds has some utility in the assessment of access patency, yet can be highly skill-dependent. The objective of the study was to identify acoustic parameters that are related to changes in vascular access patency. The underlying hypothesis is that stenoses of haemodialysis access vessels or grafts cause vascular sound changes that are detectable using computerised data acquisition and analysis. Eleven patients participated in the study. Their vascular sounds were recorded before and after angiography, which was accompanied by angioplasty in most patients. The sounds were acquired using two electronic stethoscopes and then digitised and analysed on a personal computer. Vessel stenosis changes were found to be associated with changes in acoustic amplitude and/or spectral energy distribution. Certain acoustic parameters correlated well (correlation coefficient=0.98, p<0.0001) with the change in the degree of stenosis, suggesting that stenosis severity may be predictable from these parameters. Parameters also appeared to be sensitive to modest diameter changes (>20%), (p<0.005, Wilcoxon rank sum test). These results suggest that computerised analysis of vascular sounds may be useful in vessel patency surveillance. Further testing using longitudinal studies may be warranted.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Akay, M., Akay, Y., Welowitz, W., Semmlow, J. L., andKostis, J. B. (1992): ‘Application of adaptive filters to noninvasive acoustical detection of coronary occlusions before and after angioplasty’,IEEE Trans. Biomed. Eng.,39, pp. 176–183.

    Article  Google Scholar 

  • Akay, Y., Akay, M., Welkowitz, W., Lewkowicz, S., andPalti, Y. (1994): ‘Dynamics of sounds caused by partially occluded fermoral arteries in dogs’,Ann. Biomed. Eng.,22, pp. 493–500

    Google Scholar 

  • Ask, P., Hok, B., Loyd, D., andTerio, H. (1995): ‘Bio-acoustic signals from stenotic tube flow: state of the art and perspectives for future methodological development’,Med. Biol. Eng. Comput.,33, pp. 669–675

    Google Scholar 

  • Beathard, G. (1995): ‘Percutaneous angioplasty for the treatment of venous stenosis: A nephrologists view’,Sem. Dial.,8, pp. 166–170

    Google Scholar 

  • Besarab, A., Sullivan, K., Ross, R., andMoritz, M. (1995): ‘Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis’,Kid. Int.,47, pp. 1364–1373

    Google Scholar 

  • Bosman, P., Boereboom, F., Smits, H., Eikelboom, B., Koomans, H., andBlankestijn, P. (1997): ‘Pressure of flow recordings for the surveillance of hemodialysis grafts’,Kid. Int.,52, pp. 1084–1088

    Google Scholar 

  • Burger, H., Zijlstra, J., Kluchert, S., Scholten, A., andKootstra, G. (1990): ‘Percutaneous transluminal angioplasty improves longevity in fistulae and shunts for hemodialysis’,Nephrol. Dial. Trans.,5, pp. 608–611

    Google Scholar 

  • Etheredge, E., Haid, S., Maeser, M., Sicard, G., andAnderson, C. (1983): ‘Salvage operations for malfunctioning polytetrafluoroethylene haemodialysis access grafts’,Surgery,94, pp. 464–470

    Google Scholar 

  • Fredberg, J. (1977): ‘Origin and character of vascular murmers: Model studies’,J. Acoust. Soc. Am.,61, pp. 1077–1085

    Article  Google Scholar 

  • Hodges, T., Fillinger, M., Zwolak, R., Walsh, D., Bech, F., andCronenwett, J. (1997): ‘Longitudinal comparison of dialysis access methods: Risk factors for failure’,J. Vasc. Surg.,26, pp. 1009–1019

    Article  Google Scholar 

  • Katz, S., andKohl, R. (1995): ‘The percutaneous treatment of angioaccess graft complications’,Am. J. Surg.,170, pp. 238–242

    Google Scholar 

  • Kirkeeide, R., Young, D., andCholvin, N. (1997): ‘Wall vibrations induced by flow through simulated stenosis in models and arteries’,J. Biomech.,10, pp. 431–441

    Google Scholar 

  • Kurokawa, Y., Abiko, S., andWatanabe, K. (1994): ‘Noninvasive detection of intracranial vascular lesions by recording blood flow sounds’,Stroke,25, pp. 397–402

    Google Scholar 

  • Mansy, H., Balk, R., Royston, T., andSandler, R. (2002): ‘Pneumothorax detection using computerized analysis of breath sounds’,Med. Biol. Eng. Comput.,40, pp. 526–532

    Google Scholar 

  • National Kidney Foundation (1997): ‘NKF-DOQI clinical practice guidelines for vascular access. National Kidney Foundation-Dialysis Outcomes Quality Initiative’,Am. J. Kid. Dis.,30, pp. S150-S191

    Google Scholar 

  • Owsley, N. (1998): ‘Beamformed nearfield imaging of simulated coronary artery containing a stenosis’,IEEE Trans. Med. Imag.,17, pp. 900–909

    Google Scholar 

  • Palder, S., Kirkman, R., Whittemore, A., Hakim, R., Lazarus, J., andTilney, N. (1985): ‘Vascular access for hemodialysis: Patency rates and results of revision’,Ann. Surg.,202, pp. 235–239

    Google Scholar 

  • Pasterkamp, H., Kraman, S., Defrain, T., andWodicka, G. (1995): ‘Measurement of respiratory acoustical signals: Comparison of sensors’,Chest,104, pp. 1518–1525

    Google Scholar 

  • Semmlow, J., Welkowitz, W., Kostis, J., andAkay, M. (1991): ‘Noninvasive diagnostic system for coronary artery disease’. US Patent 5,036,857

  • Tessitore, N., Bedogna, V., Gammaro, L., Lipari, G., Poli, A., Baggio, E., Firpo, M., Morana, G., Mansueto, G., andMaschio, G. (2003): ‘Diagnostic accuracy of ultrasound dilution access blood flow measurements in detecting stenosis and predicting thrombosis in native forearm arteriovenous fistulae for hemodialysis’,Am. J. of Kid. Dis.,42, pp. 331–341

    Google Scholar 

  • Tobin, R. (1976): ‘Wall pressure spectra scaling downstream of stenosis in steady pipe flow’,J. Biomech.,9, pp. 633–640

    Article  Google Scholar 

  • Wang, J., Tie, B., Welkowitz, W., Semmlow, J., andKostis, J. (1990): ‘Modeling sound generation in stenosed coronary arteries’,IEEE Trans. Biomed. Eng.,37, pp. 1087–1094

    Article  Google Scholar 

  • Windus, D., Audrain, J., Vanderson, R., Jendrisak, M., Picus, D., andDelmez, J. (1990): ‘Optimization of high-efficiency hemodialysis by detection and correction of fistula dysfunction’,Kid. Int.,38, pp. 337–341

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mansy, H.A., Hoxie, S.J., Patel, N.H. et al. Computerised analysis of auscultatory sounds associated with vascular patency of haemodialysis access. Med. Biol. Eng. Comput. 43, 56–62 (2005). https://doi.org/10.1007/BF02345123

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02345123

Keywords

Navigation