Skip to main content
Log in

Evaluation of sperm specific lactate dehydrogenase isoenzyme C4 (LDH C4) — Application to semen detection in stains

  • Case Reports
  • Published:
International Journal of Legal Medicine Aims and scope Submit manuscript

Summary

The usefulness of LDH C (or LDH X) as a semen-specific marker has been tested. Many different methods have been applied for identification using various electrophoretic methods such as agarose gel electrophoresis, IEF, rocket-immunoelectrophoresis with subsequent enzymatical, immunological and immunochemical detection methods. Further methods applied were dot blot analysis for LDH C and PCR analysis for X/Y-chromosome differentiation. In blood/semen mixtures the LDH C-bands were detectable in dilutions up to 50-fold after staining for total LDH activity. An appropriate extraction procedure was developed. Immunological tests using a polyclonal antibody against LDH C were found to be highly specific and highly sensitive. The immunological test gave positive results with azoospermic stains up to a few weeks and in normal sperm stains positive reactions were obtained even after 8 months storage. A comparison of different detection methods for semen showed that immunological detection methods for LDH C are, at least after longer time periods of storage, superior to microscopical detection. — Swabs showed positive LDH C-reactions up to 48 h after intercourse. This reaction was closely correlated to PCR for male cells and to microscopical searching.

Zusammenfassung

Untersucht wurde die Anwendbarkeit des LDH C (oder LDH X) als spermien-spezifischer Marker. Zahlreiche Verfahren stehen für Identifikations-untersuchungen unter Verwendung verschiedener elektrophoretischer Methoden wie Agarose-Gelelektrophorese, IEF, „Rocket-Immunoelektrophorese” in Kombination mit enzymatischen, immunologischen und immunochemischen Detektionsmethoden zur Verfügung. Weitere Methoden sind die Dot blot-Analyse für LDH C und die PCR-Analyse zur X/Y-Chromosom-Bestimmung. In Blut/Sperma-Mischungen sind die LDH C-Banden noch in bis zu 50-fachen Verdünnungen nach Anfärbung zur Bestimmung der LDH-Gesamtaktivität nachweisbar. Es wurde ein adäquates Extraktionsverfahren entwickelt. Immunologische Tests unter Verwendung von polyklonalen Antikörpern gegen LDH C waren hochspezifisch und sehr sensitiv. Die immunologischen Untersuchungen führten zu positiven Ergebnissen mit Spuren von azoospermischen Männern über einen Zeitraum von mehreren Wochen. Für spermienhaltige Spuren konnten bis zu einem Lagerungsalter von 8 Monaten positive Ergebnisse erzielt werden. Ein Vergleich über verschiedene Nachweismethoden für Spermien zeigte, daß — auch nach längeren Lagerungszeiträumen — die immunologischen Nachweismethoden für LDH C mikroskopischen Spermien-Nachweisen überlegen sind. Vaginalabstriche lieferten positive LDH C-Reaktion bis zu 48 Stunden nach Geschlechtsverkehr. Diese Ergebnisse waren eng korreliert zu PCR-Nachweisen der männlichen Zellen und zu mikroskopischen Untersuchungen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. kane A, Shiono H, Matsubara K, Nakahori Y, Seki S, Nagafuchi S, Yamada M, Nakagome Y (1991) Sex identification of forensic specimens by polymerase chain reaction (PCR): two alternative methods. Forensic Sci Int 49:81–88

    Google Scholar 

  2. Allen RC, Graves G, Budowle B (1989) Polymerase chain reaction amplification products separated on rehydratable polyacrylamide gels and stained with silver. BioTechniques 7:735–744

    Google Scholar 

  3. Farriaux J-P, Muller PH, Fontaine G (1967) Les isoenzymes de l'actiodehydrogenase du sperm human: Application medicolegale a l'identification d'une tache de sperme. Acta Med Leg Soc (Liege) 20:17

    CAS  Google Scholar 

  4. Gaensslen RE (1983) Sourcebook in forensic serology, immunology and biochemistry. National Institute of Justice, UD Government Printing Office,Washington DC

    Google Scholar 

  5. Gill P, Jeffreys AJ, Werrett DJ (1985) Forensic application of DNA “fingerprints”. Nature 318:577–579

    Article  CAS  PubMed  Google Scholar 

  6. Goldberg E (1977) Isozymes in testes and spermatozoa. Isozymes. Curr Top Biol Med Res 1:79–124

    CAS  Google Scholar 

  7. Mokashi RH, Madiwale MS (1976) The use of sperm lactate dehydrogenase isoenzyme for the identification of semen in dried stains. Forensic Sci 8:269–275

    Article  CAS  PubMed  Google Scholar 

  8. Oya M, Kido A, Yada S (1977) Lactatdehydrogenase-Isozym X (LDH-X) als Hilfsmittel für den Nachweis von Ejakulatspuren in der Scheide. Arch Kiminol 160:115–118

    CAS  Google Scholar 

  9. Oya M, Kido A, Komatsu N, Kitahara N (1991) Zur praktischen Anwendbarkeit der LDH-X Bestimmung zum Nachweis von Spermaspuren. Arch Kriminol 187:91–95

    CAS  PubMed  Google Scholar 

  10. Pawlowski R, Hauser R, Raszeja S (1988) Zur Stabilität ausgewählter Spermabestandteile in einem Gemisch von Sperma und Vaginalsekret. Beitr Gerichtl Med 46:219–226

    CAS  PubMed  Google Scholar 

  11. Schmechta H (1975) Nachweisbarkeit und spurenkundlicher Wert der Isoenzyme der Laktatdehydrogenase bei der Untersuchung von Spuren. Dtsch Gesundheitswes 30:2443–2446

    CAS  Google Scholar 

  12. Shaler RC (1981) A multi-enzyme electrophoretic system for the identification of seminal fluid from postmortem specimens. Am J Forensic Med Pathol 2:315–321

    CAS  PubMed  Google Scholar 

  13. Weeke B (1973) Rocket immunoelectrophoresis. In: Axelsen NH, Krolland J, Weeke B (eds) A manual of quantitative immunoelectrophoresis, pp 37–46

  14. Wheat TE, Goldberg E (1983) Sperm-specific lactate dehydrogenase C4: antigenic structure and immunosuppresion of fertility. Isozymes. Curr Top Biol Med Res 7:113–130

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pawlowski, R., Brinkmann, B. Evaluation of sperm specific lactate dehydrogenase isoenzyme C4 (LDH C4) — Application to semen detection in stains. Int J Leg Med 105, 123–126 (1992). https://doi.org/10.1007/BF02340837

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02340837

Key words

Schlüsselwörter

Navigation