Skip to main content
Log in

Active damping of a stiff beam-like structure with acceleration feedback

  • Published:
Experimental Mechanics Aims and scope Submit manuscript

Abstract

This paper describes a local control scheme using acceleration feedback and a colocated proof-mass actuator for active damping of structures. The closed-loop system is unconditionally stable. The control law is implemented digitally on a stiff beam (f 1=68 Hz) representative of an optical test bench. The modal damping ratio is improved from below 0.2 percent to above 4 percent.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Simonis, M. and Malaise, D., Banc de Test de Performances Optiques Sous Vide Thermique de Spacebel Instrumentation, Note Interne 91006 (1991).

  2. Gevarter, W.B., Basic Relations for Control of Flexible Vehicles.AIAA J. 8 (4),666–672 (April 1970).

    Google Scholar 

  3. Cannon, R.H. andRosenthal, D.E. Experiment in Control of Flexible Struetures with Noncolocated Sensors and Actuators, AIAA. J. of Guidance,7 (5),546–553 (Sept.–Oct. 1984).

    Google Scholar 

  4. Aubrun, J.N., Theory of the Control of Structures by Low-Authority Controllers, AIAA J. of Guidance,3 (5),444–451 (Sept–Oct. 1980).

    MATH  MathSciNet  Google Scholar 

  5. Fanson, J.L. andCaughey, T.K., Positive Position Feedback Control for Large Space Structures,”AIAA J.,28 (4),717–724 (April 1990).

    Google Scholar 

  6. Preumont, A., Dufour, J.P. andMalekian, C., Active Damping by a Local Force Feedback with Piezoelectric Actuators, AIAA J. of Guidance,15 (2),390–395 (March–April 1992).

    Google Scholar 

  7. Sim, E. and Lee, S. W., Active Vibration Control of Flexible Structures with Acceleration or Combined Feedback, SDM Conference, Long-Beach, AIAA paper 91-1015-CP (1991).

  8. Zimmerman, D.C., Horner, G.C. andInman, D.J., Microprocessor Controlled Force Actuator.AIAA J. of Guidance,11 (3),230–236 (May–June 1988).

    Google Scholar 

  9. Zimmerman, D.C. andInman, D.J., On the Nature of the Interaction Between Structures and Proof-Mass Actuators, AIAA J. of Guidance,13 (1),82–88 (Jan.–Feb. 1990).

    Google Scholar 

  10. Preumont, A. and Loix, N., Robust Active Damping with Acceleration Feedback, Conference on Active Control in Mechanical Engineering, Lyon (F) (June 1993).

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Preumont, A., Loix, N. Active damping of a stiff beam-like structure with acceleration feedback. Experimental Mechanics 34, 23–26 (1994). https://doi.org/10.1007/BF02328438

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02328438

Keywords

Navigation