Experimental Mechanics

, Volume 41, Issue 1, pp 47–51 | Cite as

Errors in crack closure measurements caused by flexure test fixture support effects

  • S. Johansson
  • M. E. Fitzpatrick
Article

Abstract

Flexural tests are sometimes used for the evaluation of fatigue and fracture properties, especially for thin cross sections such as plate material where compact tension speciments cannot be used, or where material thicness is limited in the direction required for data generation. The method is also useful for evaluation of crack closure provided the force transfer occurs correctly. This paper shows how the influence of incorrect test fixture supports, which are outside the standard testing arrangement for such test specimens, can affect the force-displacement curves as evidenced using the backface strain method. The results show that incorrect test fixture supports may cause deviations in the force-displacement trace as an artifact of the testing conditions. This effect can severely influence crack closure measurements. The effect was also modeled with finite element analysis.

Key Words

Flexural bend testing fatigue crack closure back-face strain strain gage techniques 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Hoagland, R.G., Marshall, C.W., andDuckworth, W.H., “Reduction of Errors in Ceramic Bend Tests,”J. Am. Cer. Soc.,56 (5–6),189–192 (1976).Google Scholar
  2. 2.
    “Determination of Plane Strain Fracture Toughness,” BS EN ISO 1237, British Standards Institution (1999).Google Scholar
  3. 3.
    Choi, S.R. andSalem, J.A., “Errors Identified As Hysteresis in Flexure Testing of Advanced Ceramics,”Scripta Materalia,35,491–494 (1996).Google Scholar
  4. 4.
    Deans, W.F. andRichards, C.E., “A Simple and Sensitive Method of Monitoring Crack and Load in Compact Fracture Mechanics Specimen Using Strain Gages,”J. Test. Eval.,7 (3),147–154 (1979).Google Scholar
  5. 5.
    Salem, J.A. andGhosn, L.S., “Back Face Strain As a Method for Monitoring Stable Crack Extension in Ceramics,”Cer. Eng. Sci. Proc.,19A,587–594 (1998).Google Scholar
  6. 6.
    Salem, J.A., Ghosn, L.J., and Jenkins, M.G., “A Strain Gage Technique to Measure Stable Crack Extension in Ceramics,” Society for Experimental Mechanics Spring Conference on Experimental Mechanics (1997).Google Scholar
  7. 7.
    Elber, W., “The Significance of Fatigue Crack Closure,”Damage Tolerance in Aicraft Structures.ASTM STP 486.American Society for Testing and Materials, Philadelphia, 230–242 (1971).Google Scholar
  8. 8.
    James, M.J. andKnott, J.F., “Critical Aspecets of the Characterisation of Crack Tip Closure by Compliance Technique,”Mat. Sci. Eng.,72,1–4 (1985).CrossRefGoogle Scholar

Copyright information

© Society for Experimental Mechanics, Inc. 2001

Authors and Affiliations

  • S. Johansson
    • 1
  • M. E. Fitzpatrick
    • 2
  1. 1.Department of Mechanical EngineeringDivision of Engineering MaterialsLinköping UniversityLinköpingSweden
  2. 2.Department of Materials EngineeringOpen UniversityMilton KeynesUnited Kingom

Personalised recommendations