Sweep technique to measure the relative performance of dampers

  • Published:
Experimental Mechanics Aims and scope Submit manuscript

Abstract

The sweep technique described in this paper represents a new method for measuring the relative performance of different dampers. Based on laboratory measurements, the technique is easy to use and keeps test execution time to a minimum. It also allows measurement of the relative performance of nonlinear dampers for which it is difficult to derive the analytical expression for their mechanical impedance. In addition to describing the test setup, the paper also presents results obtained from the application of this technique to four types of commercial dampers.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. EPRI Transmission Line Reference Book—Wind-Induced Conductor Motion, Electric Power Res. Inst. (1979).

  2. Cloutier, L.J., Hardy, C. and Brunelle, J., “The Magdalen Islands Test Line: A Research Tool for Studies of Bundle Conductor Dynamics,” IEEE, Paper No. C74-370-3 (1974).

  3. Jamaleddine, A., “Field Tests on the Performance of Various Protective Devices Against Eolian Vibration,” CEA Paper 82-TR-240 (1982).

  4. Claren, R. and Diana, G., “Mathematical Analysis of Transmission Line Vibration,” IEEE Paper 31C83, IEEE Trans. PAS,PAS-88 (12), (1969).

  5. Allnut, J.G. and Rowbottom, M.D., “Damping of Aeolian Vibration on Overhead Lines by Vibration Dampers,” Paper 7235P (1974).

  6. Pullen, J., “The Control of Aeolian Vibration in Single-Conductor Transmission Lines,” IEEE Conf. Publ. 79-PWR (1970).

  7. Simmons, J.M., Gilmore, K.L. and Dulhurty, P.W., “Damping of Electrical Transmission Lines. Part I — Analysis and Numerical Simulation,” IEEE Conf. No. 176 (1979).

  8. Sathikh, S. and Chari, R.T., “Acceptance Curve — a Practical Means for EHV Transmission Line Damper Performance Evaluation,” Electric Power Systems Research,4 (1981).

  9. IEEE Guide on the Measurement of the Performance of Aeolian Vibration Dampers for Single Conductors, IEEE Std 664-1980.

  10. IEEE Std 563-1978, Guide on Conductor Self-Damping Measurements.

  11. Noiseux, D., “Notes d'analyse des vibrations d'un cable de garde avec amortisseur,” internal report, IREQ (1977).

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jamaleddine, A. Sweep technique to measure the relative performance of dampers. Experimental Mechanics 25, 354–359 (1985). https://doi.org/10.1007/BF02321333

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02321333

Keywords

Navigation