Summary
With this inductive axial-strain-measurement device with a small and variable measurement basis, strains from a static-tension test up to the fatigue-limit range can be made.
References
Crews, J. H. andHardrath, H. F., “A Study of Cyclic Plastic Stresses at Notch Root,”Experimental Mechanics,6 (6),313–320 (June 1966).
Krempl, E., “Evaluation of High-elongation Foil Strain Gages for Measuring Cyclic Plastic Strains,”Experimental Mechanics,8 (8),19N-26N (August 1968).
Gowda, C. V. B. andTopper, T. H., “Performance of Miniature Resistance Strain Gages in Low-cycle Fatigue,”Experimental Mechanics,10 (1),27N-38N (January 1970).
Klee, S., “Das zyklische Spannungs- Dehnungs- und Bruchverhalten verschiedener Stähle,” Veroeffentlichungen des Institutes für Statik und Stahlbau der T. H. Darmstadt, Heft 22.
Wellinger, K., Gassmann, H. und Luithle, J., “Zeitfestigkeit und Dehnungsformzahl gekerbter Flachproben,” Konstruktion 21 (1969),Heft 6.
Nowack, H., “Ein Beitrag zur Untersuchung der Schadensakkumulation auf der Grundlage biharmonischer Belastungsabläufe,” Deutsche Luft- und Raumfahrt, Forschungsbericht 71-23, DFVLR Institut für Werkstoff-Forschung, Porz Wahn.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wilhelm, N. An inductive axial-strain-measurement device for fatigue investigations at notch root. Experimental Mechanics 15, 19N–20N (1975). https://doi.org/10.1007/BF02318365
Issue Date:
DOI: https://doi.org/10.1007/BF02318365