The results of an experimental and analytical program designed to evaluate the performance of brick veneer walls with metal-stud backups are reported. Particular reference is made to the performance of the walls after a crack develops in the brick veneer. The project included testing of wall ties, flexural testing of full-scale wall systems, and water-permeance testing. Six full-scale walls were tested. three with positive pressure and three with negative pressure. The walls were tested to load levels up to three times the load recommended by the metal-stud manufacturers. The lateralload test results are reported in the form of deflection profiles at various load levels.
Test results show that a large proportion of the lateral load is transferred to the metal-stud backup after a crack develops in the brick veneer.
Similar content being viewed by others
References
Brick Veneer Panel and Curtain Walls, BIA Technical Notes on Brick Construction, 28B Revised, Brick Inst. of Amer., McLean, VA (Jan./Feb. 1980).
USG Research Report No. 10556, Supplement No. 3, U.S. Gypsum, Chicago (1964).
Arumala, J.O., Structural Behavior of Wall Systems Made of Brick Veneer with Steel Stud Backup, PhD diss., Clemson Univ., Clemson, SC (1982).
Recommended Practice for Engineered Brick Masonry, Brick Inst. of Amer., McLean, VA (1969).
Water Permeance of Masonry, ASTM E 514-79, Amer. Soc. for Test. and Mat., Philadelphia (1979).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Arumala, J.O. The cracking behavior of brick walls with steel-stud backup. Experimental Mechanics 28, 177–181 (1988). https://doi.org/10.1007/BF02317569
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02317569