Skip to main content
Log in

H-point standard additions method for resolution of overlapped chromatographic peaks with a conventional fluorescence detector. Determination of phenol and cresols in waters

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

The H-Point Standard Additions Method (HPSAM) is proposed in order to resolve overlapping peaks in liquid chromatography by using a conventional fluorescence detector. The method uses as analytical signals the heights or the areas obtained at two previously selected emission wavelengths, and good results are obtained for highly overlapping peaks with highly overlapping fluorescence spectra. The principal benefits of the method are the ease of finding the required wavelengths, its insensitivity to changes in the retention time of the peak from one injection to another, and the possibility of using it in highly or only partially overlapping peaks. We have applied the method to the determination of phenol and cresols in water, resolving by the proposed method the overlapping peaks ofm- andp-cresol.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. B. F. Lloyd, Nature (London)231, 64 (1971).

    Google Scholar 

  2. M. J. Kerkhoff, J. D. Winefordner, Anal. Chim. Acta175, 257 (1985).

    Google Scholar 

  3. T. L. Cecil, S. C. Rutan, J. Chromatogr.556, 495 (1991).

    Google Scholar 

  4. K. Ishibashi, T. Imasaka, N. Ishibashi, Anal. Chim. Acta173, 165 (1985).

    Google Scholar 

  5. K. Tanaka, M. Saito, Analyst113, 509 (1988).

    Google Scholar 

  6. F. Bosch Reig, P. Campíns Falcó, Analyst113, 1011 (1988).

    Google Scholar 

  7. F. Bosch Reig, P. Campíns Falcó, Analyst115, 111 (1990).

    Google Scholar 

  8. P. Campíns Falcó, J. Verdú Andrés, F. Bosch Reig, C. Molíns Legua, Anal. Chim Acta302, 323 (1995).

    Google Scholar 

  9. P. Campíns Falcó, F. Bosch Reig, R. Herráez Hernández, A. Sevillano Cabeza, Anal. Chim. Acta257, 89 (1992).

    Google Scholar 

  10. F. Bosch Reig, P. Campíns Falcó, J. Verdú Andrés, J. Chromatogr. (in press).

  11. P. Campíns Falcó, J. Verdú Andrés, F. Bosch Reig, Analyst119, 2123 (1994).

    Google Scholar 

  12. B. Makuch, K. Gazda, M. Kaminski, Anal. Chim. Acta284, 53 (1993).

    Google Scholar 

  13. G. E. Batley, J. Chromatogr.389, 409 (1987).

    Google Scholar 

  14. C. H. Risner, J. Liq. Chromatog.16, 4117 (1993).

    Google Scholar 

  15. “Statistique Appliquée a l'Exploitation des Mesures”, Commissariat a l'Energie Atomique, Masson, Paris, 1978.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Verdú-Andrés, J., Bosch Reig, F. & Campíns-Falcó, P. H-point standard additions method for resolution of overlapped chromatographic peaks with a conventional fluorescence detector. Determination of phenol and cresols in waters. Chromatographia 42, 283–289 (1996). https://doi.org/10.1007/BF02290310

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02290310

Key Words