Abstract
The aim of our study was to verify whether threshold testing of the central area with a common automated perimeter could detect early glaucomatous damage. We selected 9 eyes of 9 patients with suspected primary open angle glaucoma and normal visual fields and 18 eyes of 18 age-matched normal subjects. They underwent the Macula Threshold Test of the Humphrey Field Analyzer using white and blue targets.
We found no significant difference in retinal sensitivity to white targets between the two groups. Sensitivity to blue targets was significantly lower among glaucoma suspects (18.43±1.14 dB) than in the control group (22.37±0.94 dB) p<0.001). Blue thresholds related significantly to age only in normals (p=0.028) while in glaucoma suspects they were strongly related to vertical cup/disc ratios (p<0.001). These results suggest that it is possible to detect early central visual disturbances from glaucoma using an automated perimeter and its built-in color filters.
Similar content being viewed by others
References
Adams AJ, Heron G, Husted R. Clinical measures of central visual function in glaucoma and ocular hypertension. Arch Ophthalmol 1987; 105: 782–7.
Anctil JL, Anderson DR. Early foveal involvement and generalized depression of the visual field in glaucoma. Arch Ophthalmol 1984; 102: 363–70.
Capoferri C, Garavaglia A, Buscemi M, Galli L, Brancato R. Perimetria automatica in soglia della regione foveale e danni glaucomatosi precoci. Risultati preliminari. Ann Ottal 1988; 114: 151–6.
Drance SM, Lakowski R, Schulzer M, Douglas GR. Acquired color vision changes in glaucoma. Use of 100-Hue test and Pickford anomaloscope as predictors of glaucomatous field change. Arch Ophthalmol 1981; 99: 829–31.
Flammer J, Bebie H. Lens opacity meter: a new instrument to quantify lens opacity. Ophthalmologica 1987; 195: 69–72.
Foulds WS, Chisholm I, Bronte-Stewart J. Effects of raised intraocular pressure on hue discrimination. Mod Probl Opthalmol 1974; 13: 328–34.
François J, Verriest G. Les dyschromatopsies acquisées dans le glaucome primaire. Ann Oculist 1959; 192: 191–9.
Genio C, Friedmann AI. A comparison between white light and blue light on about 70 eyes of patients with early glaucoma using the Mark II Visual Field Analyser. Doc Ophthal Proc Series 26, ed. by Greve E.L. & Verriest G. The Hague: Junk Publishers 1981: 207–14.
Lewis RA, Johnson CA. Early detection of glaucomatous damage. I. Psychophysical disturbances. Surv Ophthalmol 1985; 30: 111–7.
Logan N, Anderson DR. Detecting early glaucomatous visual field changes with a blue stimulus. Am J Ophthalmol 1983; 95: 432–4.
Quigley HA, Addicks EM, Green WR. Optic nerve damage in human glaucoma. III. Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathy. Arch Ophthalmol 1982; 100: 135–46.
Quigley H.A. Early detection of glaucomatous damage. II. Changes in the appearance of the optic disk. Surv Ophthalmol 1985; 30: 111–26.
Quigley HA, Dunkelberger GR, Sanchez RM. Chronic experimental glaucoma causes selectively greater loss of larger optic nerve fibers. Invest Ophthalmol Vis Sci 1986; 27 (suppl. 3): 42.
Werner EB, Saheb N, Thomas D. Variability of static visual threshold responses in patients with elevated IOPs. Arch Ophthalmol 1982; 100: 1627–31.