Skip to main content
Log in

A micro-scale method employing surface plasmon resonance detection for the determination of conditions for immunoaffinity chromatography of proteins

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

The BIAcoreTM Biosensor System utilizes a detection principle known as Surface Plasmon Resonance (SPR) which, in simple terms, detects changes in the refractive index of a solution in contact with a gold film. The gold film is surface modified with carboxymethylated dextran to produce a hydrophillic matrix onto which macromolecules may be covalently immobilized. In this respect, the BIAcoreTM is similar to any other insoluble matrix, such as a chromatographic support. The SPR detection principle, however, allows one to directly ‘visualize’ the interaction under study, in real time and without the need for reporter molecules such as enzyme-labels. In addition, the very small sample requirements, automated robotics unit and ease of data analysis suggest the potential use of the BIAcoreTM instrumentation for assay development and possibly process development, especially where bio-specific interactions such as immunoaffinity chromatography are used as a step in the process. In this report, we demonstrate the use of the BIAcoreTM SPR detector for the micro-scale determination of conditions for immunoaffinity chromatography of soluble complementreceptor 1, sCR1.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. B. Liedberg, C. Nylander, I. Lundstrom, Sensors and Actuators4, 299 (1983).

    Article  Google Scholar 

  2. D. C. Cullen, R. G. V. Brown, C. R. Lowe, Biosensors3, 211 (1987).

    Article  PubMed  Google Scholar 

  3. R. P. H. Kooyman, H. Kolkman, J. Van Gent, J. Greve Analytica Chemica213, 35 (1988).

    Article  Google Scholar 

  4. C. S. Mayo, R. B. Hallock, J. Immunol. Methods120, 105 (1989).

    Article  PubMed  Google Scholar 

  5. S. Sjölander, C. Urbansky, Anal. Chem.63, 2338 (1991).

    Article  PubMed  Google Scholar 

  6. U. Jonsson, in “Biosensors: Fundamentals, Technologies and Applications”,F. Schiller, R. D. Schmid, eds., VCH, 1992, p. 467.

  7. S. Löfas, B. Johnson, J. Chem. Soc., Chem. Commun.21, 1526 (1990).

    Google Scholar 

  8. H. Weisman, T. Bartow, M. Leppo, H. Marsh, G. Carson, M. Concino, M. Boyle, K. Roux, M. Weisfeldt, D. Fearon, Science249, 146 (1990).

    Google Scholar 

  9. M. Mulligan, C. G. Yeh, A. Rudolph, P. Ward, J. Immunol.148, 1479 (1992).

    PubMed  Google Scholar 

  10. W. Wong, R. Jack, J. Smith, C. Kennedy, D. Fearon, J. Immunol. Meth.82, 303 (1985).

    Article  Google Scholar 

  11. M. Brigham-Burke, J. Edwards, D. O'Shannessy, Anal. Biochem.205, 125 (1992).

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Brigham-Burke, M., O'Shannessy, D.J. A micro-scale method employing surface plasmon resonance detection for the determination of conditions for immunoaffinity chromatography of proteins. Chromatographia 35, 45–49 (1993). https://doi.org/10.1007/BF02278555

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02278555

Key Words

Navigation