Skip to main content
Log in

Peak recognition technique by a computer program copying the human judgement

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

It is still difficult to determine peaks and peak boundaries properly, though peak recognition is very important for the precision of quantitative data. A new computer program overcomes these problems using a method which is adapted from human judgements. The algorithm was developed for HPLC but can also be used in other fields of analytical chemistry.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. W. Garbade, doctoral thesis Würzburg 1985.

  2. G. Reich, Chromatographia24, 659 (1987).

    Google Scholar 

  3. S. Ebel, M. Herboth, H. Wätzig, Software-Entwick. Chem.2, Proc. Workshops “Comput. Chem.”, 2nd meeting date 1987, 267–290.

  4. J. Hartung, Statistik. Oldenbourg Verl. München, 1st ed. 1982.

  5. H. Mager, Moderne Regressionsanalyse. Otto Salle Verl. Frankfurt/M., 1st ed. 1982.

    Google Scholar 

  6. P. J. Rousseeuw, A. M. Leroy, Robust Regression and Outlier Detection, Wiley, New York 1987.

    Google Scholar 

  7. S. Ebel, H. Wätzig, Software-Entwick. Chem. 5, Proc. Workshops “Comput. Chem.”, 5nd meeting date 1990, in press.

  8. P. Fleischer, doctoral thesis Würzburg 1989.

  9. G. Wahba, J. R. Statist. Soc. B45, 133 (1983).

    Google Scholar 

  10. DIN-Entwurf 32645, Nachweis- und Bestimmungsgrenze. Arbeitsausschuß Chemische Terminologie (AChT) 1989.

  11. G. Dertinger, H. Gänshirt, M. Steiningen, GAP: Praxisgerechtes Arbeiten in pharmazeutisch-analytischen Laboratorien. Proc. Sympos. Mainz 28/29.04. 1983.

  12. H. Wätzig, Statistische Qualitätskontrolle. Hagers Handbuch der Pharmazeutischen Praxis, Vol. 2, E. Nürnberg, P. Surmann (ed.), 5th ed., 1048–84.

  13. U. Hoffmann, doctoral thesis Würzburg 1991.

  14. S. J. Nelson, T. R. Brown, Bull. Magn. Reson.,11(3–4), 290–293 (1989).

    Google Scholar 

  15. S. J. Nelson, T. R. Brown, J. Magn. Reson.84, 95–109 (1989).

    Google Scholar 

  16. S. J. Nelson, T. R. Brown, J. Magn. Reson.75, 229–243 (1987).

    Google Scholar 

  17. A. Rosenfeld, A. C. Kak, Digital Picture Processing, Vol 1 & 2, Academic Press, New York 1982.

    Google Scholar 

  18. N. Dyson, Chromatographic Integration Methods. Royal Soc. of Chemistry, 1990.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wätzig, H. Peak recognition technique by a computer program copying the human judgement. Chromatographia 33, 218–224 (1992). https://doi.org/10.1007/BF02276186

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02276186

Key Words

Navigation