Skip to main content
Log in

The quantitative effect of microextractor cell geometry on the analytical supercritical fluid extraction efficiencies of environmentally important compounds

  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

The quantitative effect of microextractor cell geometries on supercritical fluid extraction (SFE) efficiencies of polycyclic aromatic hydrocarbons (PAHs) and methoxychlor from octadecyl-bonded sorbents has been evaluated and compared to similar effects seen upon increasing the supercritical fluid density. For the PAHs studied, correlations between the fused ring number and the relative increase in recoveries have been established. SFE recoveries can be increased by greater than a factor of two by decreasing the diameter to length ratio from 1∶20 to 1∶1. The relative recovery increase upon decreasing the diameter to length ratio of the extraction vessel is dependent on the analyte extractability, increasing in proportion to the fused ring number for the PAHs. Recoveries increased linearly as a function of supercritical fluid density for the PAHs studied. The change in the relative recovery upon increasing the supercritical carbon dioxide density again was dependent on the analyte type, decreasing linearly with fused ring number. Although fluid density generally had the greatest effect on achievable SFE recoveries, the cell geometry had effects of a similar order of magnitude, highly dependent on the initial extractability of the analyte.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. M.A. McHugh, V.J. Krukonis, Supercritical fluid Extraction: Principles and Practice, Butterworths, Boston, 1986.

    Google Scholar 

  2. B.A. Charpentier, M.R. Sevenants (eds.), Supercritical Fluid Extraction and Chromatography, ACS Symposium Series 366, American Chemical Society, Washington, 1988.

    Google Scholar 

  3. K.P. Johnston, J.M.L. Penninger (eds.), Supercritical Fluid Science and Technology, ACS Symposium Series 406, American Chemical Society, Washington, 1989.

    Google Scholar 

  4. S.B. Hawthorne, Anal. Chem.62, 633A (1990).

    Google Scholar 

  5. K.G. Furton, J. Rein, Anal. Chim. Acta236, 99 (1990).

    Google Scholar 

  6. K.G. Furton, J. Rein, Anal. Chim. Acta, in press.

  7. J. Rein, C. Cork, K.G. Furton, J. Chromatogr., submitted for publication.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Furton, K.G., Rein, J. The quantitative effect of microextractor cell geometry on the analytical supercritical fluid extraction efficiencies of environmentally important compounds. Chromatographia 31, 297–299 (1991). https://doi.org/10.1007/BF02275754

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02275754

Key Words

Navigation