Evaluation of an ion mobility detector for supercritical fluid chromatography with solvent-modified carbon dioxide mobile phases

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

An ion mobility detector (IMD) was evaluated for open tubular column supercritical fluid chromatography (SFC) when organic solvent-modified supercritical CO2 was used as mobile phase. It was found that the SFC/IMD interface design in which the SFC capillaray restrictor was directly inserted into the ionization region of the IMD was not acceptable because of low sensitivity that resulted from the effect of the modifier on detector temperature and mechanism of detection. A new interface utilizing a heated nebulizer gas to provide heat to the restrictor and to minimize the formation of ion clusters, and a bent nozzle for enhancing the ionization efficiency of the solute in the IMD ion source are described. Using 5% acetonitrile in CO2, the minimum detectable quantity (S/N=3) for pyrene was improved from 25.2 ng to 2.1 ng with the new detector design. This compares to a minimum detectable quantity of 0.1 ng when using neat CO2 as mobile phase. The use of molecular connectivity calculations to predict the drift times of selected analytes is also successfully demonstrated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. S. M. Fields, K. E. Markides, M. L. Lee, J. Chromatogr.406, 223 (1987).

    Google Scholar 

  2. J. G. M. Janssen, P. J. Schoenmakers, C. A. Cramers, J. High Res. Chromatogr.12, 645 (1989).

    Google Scholar 

  3. A. Giorgetti, N. Pericles, H. M. Widmer, K. Anton, P. Dätwyler, J. Chromatogr. Sci.27, 318 (1989).

    Google Scholar 

  4. M. A. Baim, H. H. Hill Jr., Anal. Chem.54, 38 (1982).

    Google Scholar 

  5. R. L. Eatherton, M. A. Morrissey, W. F. Siems, H. H. Hill, Jr., J. High Resolut. Chromatogr. Chromatogr. Commun.9, 154 (1986).

    Google Scholar 

  6. S. Rokushika, H. Hatano, H. H. Hill, Jr., Anal. Chem.59, 8 (1987).

    Google Scholar 

  7. M. A. Morrissey, H. H. Hill, Jr., J. Chromatogr. Sci.27, 529 (1989).

    Google Scholar 

  8. C. B. Shumate, H. H. Hill, Jr., Anal. Chem.61, 601 (1989).

    Google Scholar 

  9. D. E. Raynie, S. M. Fields, N. M. Djordevic, K. E. Markides, M. L. Lee, J. High Resolut. Chromatogr.12, 51 (1989).

    Google Scholar 

  10. Z. Bernant, Z. Karpas, O. Shahal, J. Phys. Chem.93, 7529 (1989).

    Google Scholar 

  11. F. J. Knorr, R. L. Eatherton, W. F. Siems, H. H. Hill, Jr., Anal. Chem.57, 402 (1985).

    Google Scholar 

  12. R. L. Eatherton, W. F. Siems, H. H. Hill, Jr., J. High Resolut. Chromatogr. Chromatogr. Commun.9, 44 (1986).

    Google Scholar 

  13. E. K. Whalen-Pedersen, P. C. Jurs, Anal. Chem.53, 2184 (1981).

    Google Scholar 

  14. M. N. Hasan, P. C. Jurs, Anal. Chem.,55, 263 (1983).

    Google Scholar 

  15. H. E. Revercomb, E. A. Mason, Anal. Chem.47, 970 (1975).

    Google Scholar 

  16. L. B. Kier, L. H. Hall, Molecular Connectivity in Chemistry and Drug Research, Academic Press, New York, 1976.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Huang, M.X., Markides, K.E. & Lee, M.L. Evaluation of an ion mobility detector for supercritical fluid chromatography with solvent-modified carbon dioxide mobile phases. Chromatographia 31, 163–167 (1991). https://doi.org/10.1007/BF02274566

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02274566

Key Words

Navigation