Summary
An ion mobility detector (IMD) was evaluated for open tubular column supercritical fluid chromatography (SFC) when organic solvent-modified supercritical CO2 was used as mobile phase. It was found that the SFC/IMD interface design in which the SFC capillaray restrictor was directly inserted into the ionization region of the IMD was not acceptable because of low sensitivity that resulted from the effect of the modifier on detector temperature and mechanism of detection. A new interface utilizing a heated nebulizer gas to provide heat to the restrictor and to minimize the formation of ion clusters, and a bent nozzle for enhancing the ionization efficiency of the solute in the IMD ion source are described. Using 5% acetonitrile in CO2, the minimum detectable quantity (S/N=3) for pyrene was improved from 25.2 ng to 2.1 ng with the new detector design. This compares to a minimum detectable quantity of 0.1 ng when using neat CO2 as mobile phase. The use of molecular connectivity calculations to predict the drift times of selected analytes is also successfully demonstrated.
Similar content being viewed by others
References
S. M. Fields, K. E. Markides, M. L. Lee, J. Chromatogr.406, 223 (1987).
J. G. M. Janssen, P. J. Schoenmakers, C. A. Cramers, J. High Res. Chromatogr.12, 645 (1989).
A. Giorgetti, N. Pericles, H. M. Widmer, K. Anton, P. Dätwyler, J. Chromatogr. Sci.27, 318 (1989).
M. A. Baim, H. H. Hill Jr., Anal. Chem.54, 38 (1982).
R. L. Eatherton, M. A. Morrissey, W. F. Siems, H. H. Hill, Jr., J. High Resolut. Chromatogr. Chromatogr. Commun.9, 154 (1986).
S. Rokushika, H. Hatano, H. H. Hill, Jr., Anal. Chem.59, 8 (1987).
M. A. Morrissey, H. H. Hill, Jr., J. Chromatogr. Sci.27, 529 (1989).
C. B. Shumate, H. H. Hill, Jr., Anal. Chem.61, 601 (1989).
D. E. Raynie, S. M. Fields, N. M. Djordevic, K. E. Markides, M. L. Lee, J. High Resolut. Chromatogr.12, 51 (1989).
Z. Bernant, Z. Karpas, O. Shahal, J. Phys. Chem.93, 7529 (1989).
F. J. Knorr, R. L. Eatherton, W. F. Siems, H. H. Hill, Jr., Anal. Chem.57, 402 (1985).
R. L. Eatherton, W. F. Siems, H. H. Hill, Jr., J. High Resolut. Chromatogr. Chromatogr. Commun.9, 44 (1986).
E. K. Whalen-Pedersen, P. C. Jurs, Anal. Chem.53, 2184 (1981).
M. N. Hasan, P. C. Jurs, Anal. Chem.,55, 263 (1983).
H. E. Revercomb, E. A. Mason, Anal. Chem.47, 970 (1975).
L. B. Kier, L. H. Hall, Molecular Connectivity in Chemistry and Drug Research, Academic Press, New York, 1976.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Huang, M.X., Markides, K.E. & Lee, M.L. Evaluation of an ion mobility detector for supercritical fluid chromatography with solvent-modified carbon dioxide mobile phases. Chromatographia 31, 163–167 (1991). https://doi.org/10.1007/BF02274566
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02274566