Skip to main content
Log in

Hochdruck-flüssigkeits-chromatographische Analyse der Katecholamine mit einem Äthylendiamin-Reaktionsdetektor

High-speed liquid chromatography of the catecholamines using an ethylenediamine reaction detector

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

The possibilities of a high-speed liquid chromatographic (HPLC) method using ion exchange and reversed-phase techniques for dihydroxyphenylalanine (dopa) and the catecholamines dopamine, noradrenaline, and adrenaline in combination with a reaction detector are described. The reaction detector comprises a fluorimeter and a reaction unit with liquid dose-pump. In the reaction unit the substances coming from the HPLC column react with ethylenediamine (AeDA) to form fluorescent products. By combining the HPLC separation with the selective AeDA-reaction and fluorimetric measurement a separate and sensitive analysis of components using isopropyl noradrenaline as internal standard is possible in about 20 minutes.

Zusammenfassung

Es werden die Möglichkeiten einer hochdruck-flüssigkeitschromatographischen (HPLC-) Analyse durch lonenaustausch und „reversed-phase”-Chromatographie für Dihydroxyphenylalanin (Dopa) und die Katecholamine Dipamin, Noradrenalin und Adrenalin in Verbindung mit einem Reaktionsdetektor beschrieben. Der Reaktionsdetektor besteht aus einem Fluorimeter und einer Reaktionseinheit mit Flüssigkeits-Dosierpumpe. In der Reaktionseinheit findet die Umsetzung der von der HPLC-Säule kommenden Substanze mit Äthylendiamin (AeDA) zu fluoreszierenden Reaktionsprodukten statt. Durch die Verbindung der HPLC-Trennung mit der selektiven AeDA-Reaktion und fluorimetrischen Messung ist eine getrennte und empfindliche Analyse der Substanzen unter Verwendung von Isopropyl-noradrenalin als inneren Standard in etwa 20 Minuten möglich.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Weil-Malherbe, H. undA. D. Bone, Biochem. J.51, 311 (1952).

    Google Scholar 

  2. Kojima-Sudo, A., Ind. Health12, 153 (1974).

    Google Scholar 

  3. Mori, K., Jap. J. Ind. Health17, 170 (1975).

    Google Scholar 

  4. Mori, K., Ind. Health12, 171 (1974).

    Google Scholar 

  5. Schwedt, G., J. Chromatogr., Biomed. Applic. 1977 im Druck.

  6. Knox, J. H. undA. Pryde, Advances in Chromatography, Proc. X. Int. Symp., Nov. 3.–6., 1975, München, 171 (1975).

  7. Weil-Malherbe, H., Biochem. Biophys. Acta,40, 351 (1960).

    Google Scholar 

  8. Udenfriend, S., Fluorescence Assay in Biology and Medicine II 139–157, Academic Press, New York 1969.

    Google Scholar 

  9. Burn, G. P. undE. O. Field, Nature178, 542 (1956).

    Google Scholar 

  10. Schwedt, G., unveröffentlichte Versuche.

  11. Viktora, J. K., A. Baukal undF. W. Wolff, Anal. Biochem.23, 513 (1968).

    Google Scholar 

  12. Wisser, H. undE. Knoll, Z. Klin. Chem., Klin. Biochem.11, 3 (1973).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schwedt, G. Hochdruck-flüssigkeits-chromatographische Analyse der Katecholamine mit einem Äthylendiamin-Reaktionsdetektor. Chromatographia 10, 92–96 (1977). https://doi.org/10.1007/BF02274466

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02274466

Navigation