Skip to main content
Log in

Operating the pulsed discharged detector in both the electron-capture and photoionization modes within the same GC analysis

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

Since the electron-capture detector (ECD) is highly selective, it is imperative to use a more universal ionization detector in conjunction with the ECD in order to detect non-capturing or weakly capturing compounds. Also in an EC study of weakly or moderately strong electron-capturing compounds, it is necessary to identify the EC peak of the compound by identifying the major component with an ionization detector. In this paper we have shown that the pulsed discharge detector can be interchanged between the EC and the helium ionization modes within 4–6 s. The application of this procedure has been illustrated with a mixture of alkane/alkene chlorocompounds. The interchange between EC and argon photoionization modes has also been investigated. The change from EC to argon photoionization also occurs in 4–6 s but the reverse process requires ∼9 s.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. W. E. Wentworth, S. V. Vasnin, S. D. Stearns, C. J. Meyer, Chromatographia34, 219 (1992).

    Google Scholar 

  2. W. E. Wentworth, H. Cai, J. Madabushi, Y. Qin, S. D. Stearns, C. J. Meyer, Process Control and Quality5, 193 (1993).

    Google Scholar 

  3. W. E. Wentworth, H. Cai, S. D. Stearns, J. of Chromatogr.A 688, 135 (1994).

    Google Scholar 

  4. W. E. Wentworth, E. D. D'Sa, H. Cai, S. D. Stearns, J. of Chromatogr. Sci.30, 478 (1992).

    Google Scholar 

  5. H. Cai, W. E. Wentworth, S. D. Stearns, Anal. Chem.68, 1233 (1996).

    Google Scholar 

  6. Y. Wang, W. E. Wentworth, W. Odegard, E. C. M. Chen, S. D. Stearns, J. Chromatogr. Sci.34, 368 (1996).

    Google Scholar 

  7. W. E. Wentworth, Y. L. Li, S. D. Stearns, J. High Resolution Chromatography19, 85 (1996).

    Google Scholar 

  8. G. Gremaud, W. E. Wentworth, A. Zlatkis, R. Swatloski, E. C. M. Chen, S. D. Stearns, J. of Chromatogr.A 724, 235 (1996).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wentworth, W.E., Huang, J., Chen, E.C.M. et al. Operating the pulsed discharged detector in both the electron-capture and photoionization modes within the same GC analysis. Chromatographia 43, 353–360 (1996). https://doi.org/10.1007/BF02271010

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02271010

Key Words

Navigation