Skip to main content
Log in

An all-glass solid sampling device for open tubular columns in gas chromatography

Ein Ganzglas-System zur Dosierung von Festproben auf Trennkapillaren in der Gas-Chromatographie

Dispositif d'injection tout en verre pour colonnes capillaires de chromatographie en phase gazeuse

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

An all-glass system for direct sample-introduction of high-boiling compounds onto open tubular columns is described.

The standard deviation for quantitative measurements is less than 2.7%. The loss in resolving power of capillary columns, due to this injection system is negligible. The system is extremely simple and may be connected to any type of gas chromatograph without extensive modifications. The injector appears to be suitable for the analysis of high-boiling compounds, present in trace amounts in volatile solvents. It is applied with succes for the analysis of steroids in body fluids.

Zusammenfassung

Es wird ein Ganzglas-System zur direkten Dosierung von hochsiedenden Verbindungen auf Trennkapillaren beschrieben. Die Standard-Abweichung bei quantitativen Messungen liegt unter ±2,7%. Der Verlust an Trennleistung der Kapillaren bei diesem Dosiersystem ist vernachlässigbar gering. Das System ist äußerst einfach und kann ohne nennenswerte Änderungen an jeden Gas-Chromatographen angepaßt werden. Das Einlaßsystem erscheint geeignet für die Analyse von hochsiedenden Verbindungen, die in Spurenkozentrationen in flüchtigen Lösungsmitteln vorliegen. Es wird mit Erfolg für die Analyse von Steroiden in Körperflüssigkeiten angewendet.

Résumé

On décrit un dispositif tout en verre permettant l'introduction directe, sur des colonnes capillaires, de composés à point d'ébullition élevé. La déviation standard des mesures quantitatives est plus faible que 2,7%. La perte de pouvoir séparateur des colonnes capillaires, due à ce dispositif d'injection, est négligeable. Le montage est extrêmement simple et s'adapte à tous les chromatographes en phase gazeuse sans nécessiter de modifications improtantes. L'injecteur parait convenable pour l'analyse de composés à point d'ébullition élevé présent à l'état de traces dans des solvants volatils. Il a été utilisé avec succès pour l'analyse de stéroides dans les liquides biologiques.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Rushneck, D. R., J. Gas Chromatogr.,3, 318 (1965)

    Google Scholar 

  2. Grob, K. andGrob, G., J. Chromatogr. Sci.,7, 584 (1969)

    Google Scholar 

  3. Grob, K. andGrob, G., J. Chromatogr. Sci.,7, 587 (1969)

    Google Scholar 

  4. Ros, A., J. Gas Chromatog.,3, 252 (1965)

    Google Scholar 

  5. Kuppens, P. S. H., Chemisch Weekblad65/36 (1967) 7

    Google Scholar 

  6. Kuppens, P. S. H., andde Jong, E. B. M., IIId International Congress on Hormonal Steroids, Hamburg, 7–12 September 1970

  7. Krugers, J. F. J., Thesis, Technische Hogeschool, Eindhoven, The Netherlands (1964)

  8. Groenendijk, H. andvan Kemenade, A. C. W., Chromatographia,2, 107 (1969)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

van den Berg, P.M.J., Cox, T.P.H. An all-glass solid sampling device for open tubular columns in gas chromatography. Chromatographia 5, 301–305 (1972). https://doi.org/10.1007/BF02268590

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02268590

Keywords

Navigation