Advertisement

Chromatographia

, Volume 3, Issue 5, pp 233–237 | Cite as

Gas chromatographic separation of steroids on glass capillary columns

  • J. A. Völlmin
Originals

Summary

The separation of trimethylsilyl ether derivatives of steroids was studied on glass capillary columns. Steroid reference compounds as well as steroids from biological material were injected without stream splitting and separated on phases OV 101 and SF 96. Capillary columns of this type allowed a much better gas chromatographic separation compared with packed ones. The prepurification procedure for biological material (e.g. urine samples) and the time required for a gas chromatographic run were reduced.

Keywords

Biological Material Trimethylsilyl Ether Derivative Trimethylsilyl Ether Glass Capillary Column 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Gas-chromatographische Trennung von Steroiden auf Glas-Kapillarsäulen

Zusammenfassung

Die Trennung von Trimethylsilyläther-Derivaten von Steroiden wurde auf Glas-Kapillarsäulen untersucht. Es wurden Steroid-Vergleichssubstanzen wie auch Steroide aus biologischem Material ohne Strömungsteilung eingespritzt und auf den stationären Phasen OV 101 und SF 96 getrennt. Im Vergleich zu gepackten Säulen bewirken Kapillarsäulen dieser Art eine viel bessere gas-chromatographische Trennung. Der Vorreinigungsschritt für biologisches Material (z. B. Urinproben) und die für die gas-chromatographische Analyse benötigte Zeit werden reduziert.

Separation par chromatographie en phase gazeuse de stéroides sur des colonnes capillaires en verre

Sommaire

La séparation de stéroides sous fome de triméthylsilyléthers a été étudiée sur des colonnes capillaires en verre. Des stéroides de référence ainsi que des stéroides obtenus de milieux biologiques ont été injectés sans partage du courant et séparés sur les phases stationnaires OV 101 et SF 96. Comparé aux colonnes remplies, des colonnes capillaires de ce type permettent d'obtenir une séparation bien meilleure. L'opération de prépurification pour du matériel biologique (par exemple l'urine) et le temps nécessaire pour l'analyse en phase gazeuse sont réduits.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. [1]
    T. Luukkainen, W. J. A. Vanden Heuvel, E. O. A. Haahti andE. C. Horning, Biochim. Biophys. Acta52 (1961) 599.Google Scholar
  2. [2]
    A. E. Pierce, “Silylation of organic compounds”, Pierce Chemical Company, Rockford, Illinois, 1968.Google Scholar
  3. [3]
    K. B. Eik-Nes andE. C. Horning, “Gas phase chromatography of steroids”, Springer-Verlag, Berlin 1968.Google Scholar
  4. [4]
    W. L. Gardiner andE. C. Horning, Biochim. Biophys. Acta115 (1966) 524.Google Scholar
  5. [5]
    H. M. Fales andT. Luukkainen, Anal. Chem.37, (1965) 955.Google Scholar
  6. [6]
    K. Grob andG. Grob, J. Chromatog. Sci.7 (1969) 584.Google Scholar
  7. [7]
    K. Grob, Helv. Chim. Acta51 (1968) 718.Google Scholar
  8. [8]
    K. Grob andG. Grob, J. Chromatog. Sci.7 (1969) 587.Google Scholar
  9. [9]
    H.-Ch. Curtius andM. Müller, J. Chromatog.30 (1967) 410.Google Scholar
  10. [10]
    M. Zachmann, J. A. Völlmin, G. Mürset, H.-Ch. Curtius andA. Prader, J. clin. Endocrin, in press.Google Scholar

Copyright information

© Friedr. Vieweg + Sohn GmbH 1970

Authors and Affiliations

  • J. A. Völlmin
    • 1
  1. 1.Laboratory of Clinical Chemistry Pediatric DepartmentUniversity of ZurichZurichSwitzerland

Personalised recommendations