Skip to main content
Log in

Determination of impurities in azidothymidine by HPTLC densitometry and HPLC

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

HPTLC densitometry and HPLC have been developed for the determination of potential impurities of azidothymidine (theymine, isothymidine, Az-Tr-thymidine, Ms-Tr-thymidine and Tr-alcohol). In HPTLC the substances were separated on silica gel with fluorescence indicator in 5∶95 methanol-chloroform for the simultaneous determination of Az-Tr-thymidine, Ms-Tr-thymidine and Tr-alcohol and in 10∶90 methanolchloroform for the simultaneous determination of thymine and isothymidine. Absorbance measurement (detection of reflectance) of separated substances was carried out “in situ” at 268 and 220 nm using four-level calibration (external standard) in the range of 25–100 ng thymine and isothymidine per spot. 50–200 ng Ms-Tr-thymidine and Az-Tr-thymidine per spot and 250–1000 ng Tr-alcohol per spot. For the HPLC determination of impurities two procedure are described one for thymine and isothymidine and the other for Ms-Tr-thymidine, Tr-alcohol and Az-Tr-thymidine. The first procedure was carried out using RP-18 stationary phase and methanol+aqueous 0.03 mol/l KH2PO4 (18+82, v/v) as the mobile phase. The temperature was 50°C and the detection wavelength 266 nm. In the second procedure the methanol content of the mobile phase was increased to 81% and the detection wavelength was changed to 210 nm. The detection limit of all impurities was 0.05 %. The concentration range for thymine was 1–40μg/ml and for the other impurities 1–20 μg/ml (for an injection volume of 10 μl). The results were evluated by linear regression analysis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. H. Tománková, J. Sabartová, Chromatographia29, 44 (1990).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tománková, H., Sabartová, J. Determination of impurities in azidothymidine by HPTLC densitometry and HPLC. Chromatographia 29, 562–570 (1990). https://doi.org/10.1007/BF02261223

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02261223

Key Words

Navigation