Summary

The applicability of a commercial evaporative light scattering detector (ELSD) in polymer analysis was studied in isocratic and gradient elution. The specific response is independent of the relative molecular masses of polystyrenes and of the chemical composition of styrene-acrylonitrile copolymers but is a function of eluent composition and of the air pressure used for nebulization. It also depends on linear velocity of the eluent consequently the ELSD is not a mass sensitive detector. A limiting factor is the dependence of the specific response on sample size, especially in the chromatographically important range below 30 μg. On the other hand, it is the only detector applicable to qualitative polymer analysis in gradient elution for polymers without chromophores or with non-transparent eluents.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. Stolywho, H. Colin, G. Guiochon, Anal. Chem.57, 1342 (1985)

    Google Scholar 

  2. A. Stolywho, M. Martin, G. Guiochon, J. Liq. Chromatogr.10, 1237 (1987)

    Google Scholar 

  3. J. L. Perrin, A. Prevot, A. Stolywho, G. Guiochon, Revue Francaise des Corps Gras12, 495 (1984)

    Google Scholar 

  4. J. C. Robinson, L. Macrae, J. Chromatogr.303 386 (1984)

    Google Scholar 

  5. R. Macrae, L. C. Trugo, J. Dick, Chromatographia15, 476 (1982)

    Google Scholar 

  6. W. W. Christie, M. L. Hunter, J. Lipid Res.26, 507 (1985)

    Google Scholar 

  7. N. Sotirhos, C. Thörngren, B. Herslöf, J. Chromatogr.331, 313 (1985)

    Google Scholar 

  8. W. W. Christie, M. L. Hunter, J. Chromatogr.325, 473 (1985)

    Google Scholar 

  9. R. Macrae, J. Dick, J. Chromatogr.210, 138 (1981)

    Google Scholar 

  10. T. H. Mourey, J. Chromatogr.357, 101 (1986)

    Google Scholar 

  11. P. A. Asmus, J. B. Landis, J. Chromatogr.316, 461 (1984)

    Google Scholar 

  12. J. M. Charlesworth, Anal. Chem.50, 1414 (1978)

    Google Scholar 

  13. L. E. Oppenheimer, T. H. Mourey, J. Chromatogr.298, 217 (1984)

    Google Scholar 

  14. T. H. Mourey, L. E. Oppenheimer, Anal. Chem.56, 2427 (1984)

    Google Scholar 

  15. L. E. Oppenheimer, T. H. Mourey, J. Chromatogr.323, 297 (1985)

    Google Scholar 

  16. S. Nukiyama, Y. Tanasawa, Trans. Soc. Mech. Eng. (Jpn)4, 86 (1983)

    Google Scholar 

  17. A. Stolywho, H. Colin, M. Martin, G. Guiochon, J. Chromatogr.288, 253 (1984)

    Google Scholar 

  18. A. Stolywho, H. Colin, G. Guiochon, J. Chromatogr.265, 1 (1983)

    Google Scholar 

  19. G. Guiochon, A. Moysan, C. Holley, J. Liq. Chromatogr.11, 2547 (1988)

    Google Scholar 

  20. R. Schultz, H. Engelhardt, Chromatographia29, 205 (1990)

    Google Scholar 

  21. R. Schultz, H. Engelhardt, Chromatographia29, 325 (1990)

    Google Scholar 

  22. I. Halász, Anal. Chem. 35, 1428 (1969)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schultz, R., Engelhardt, H. The application of an evaporative light scattering detector in polymer analysis. Chromatographia 29, 517–522 (1990). https://doi.org/10.1007/BF02261215

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02261215

Key Words

Navigation