Skip to main content
Log in

Determination of metoprolol in human plasma by column switching high-performance liquid chromatography

  • Short Communications
  • Published:
Chromatographia Aims and scope Submit manuscript

    We’re sorry, something doesn't seem to be working properly.

    Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Summary

Retention characteristics of metoprolol have been studied in reversed phase mode on RP2, RP8 and CN columns. The plots of retention time as a function of the acetonitrile content and of the ionic strength of the mobile phase permitted the choice of the best conditions to separate metoprolol from plasma components by switching of these three types of columns.

Human plasma (0.5–1 ml) diluted with water is first injected on a RP2 column (25–40 μm particle diameter, prepared by dry packing) and rinsed with water. The sample is then back eluted with acetonitrile-0.022 M acetate buffer (75∶25, v:v) and switched to a CN column (10 cm long, 5 μm particle diameter). The heart cut of the eluate is selected and loaded on a RP8 analytical column (25 cm long, 5 μm particle diameter) with acetonitrile-0.088 M acetate buffer (75∶25, v:v) as mobile phase.

Auto-sampler and switching valves are actuated automatically by a computing integrator based on a fixed time schedule. The duration of one cycle is about 30 min, but the last analytical step is about 15 min and represents the time interval between two injections. Metoprolol, its alpha-hydroxy metabolite and the internal standard are detected by fluorescence (λex= 225 nm; λem > 320 nm).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. C. G. Regardh, G. Johnsson, Clin. Pharmacokin5, 557 (1980).

    Google Scholar 

  2. A. Sioufi, F. Leroux, to be published.

  3. W. Roth, K. Beschke, R. Jauch, A. Zimmer, F. W. Koss, J. Chromatogr.222, 13 (1981).

    Google Scholar 

  4. J. A. Apffel, T. V. Alfredson, R. E. Majors, J. Chromatogr.206, 43 (1981).

    Google Scholar 

  5. F. Erni, H. P. Keller, C. Morin, M. Schmitt, J. Chromatogr.204, 65 (1981).

    Google Scholar 

  6. J. C. Gfeller, M. Stockmeyer, J. Chromatogr.198, 162 (1980).

    Google Scholar 

  7. H. Müller, H. W. Zulliger, B. A. Dörig, R. A. Egli, Arzneim. Forsch.32 (1), 3, 257 (1982).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lecaillon, J.B., Souppart, C. & Abadie, F. Determination of metoprolol in human plasma by column switching high-performance liquid chromatography. Chromatographia 16, 158–161 (1982). https://doi.org/10.1007/BF02258888

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02258888

Key Words

Navigation