Abstract
The equations derived to measure the calcium flow rates in the gut and blood have been applied to data gathered from 23 subjects. Each subject was given 5 μCi45Ca by intravenous injection and 20 μCi47Ca orally. The specific activities of plasma, urine and faeces were then measured and the absorption and calcium endogenous flow rates found, using both methods described in a previous publication. The measurements based on the calculations of the faecal occupancies, of the two tracers were found to be more satisfactory than the calculations based on plasma occupancy. The measurements on subjects who had gastric surgery gave some information on the site of calcium absorption.
Résumé
Les équations dérivées pour mesurer les vitesses de déplacement du calcium au niveau de l'intestin et du sang ont été appliquées à des résultats obtanus chez 23 sujets. Chaque sujet a reçu 5 μ Ci45Ca par injection intra-veineuse et 20 μ Ci47Ca per os. Les activités spécifiques du plasma, de l'urine et des fèces ont été mesurées et l'absorption et les vitesses de déplacement endogène du calcium ont été déterminées, en utilisant les deux méthodes décrites antérieurement. Les mesures basées sur les calculs du contenu des fèces en ces deux isotopes, sont plus satisfaisantes que les calculs réalisés sur le plasma. Les mesures réaliséez chez des sujets, ayant été soumis à la chirurgie gastrique, donnent certaines informations concernant les régions d'absorption du calcium.
Zusammenfassung
Die abgeleiteten Gleichungen zur Messung der Calciumdurchflußgeschwindigkeiten in Darm und Blut kamen zur Anwendung bei der Aufarbeitung von Daten, die für 23 Personen zusammengestellt wurden. Jede Versuchsperson erhielt 5 μC45Ca i. v. und 20 μC47Ca p. o. Die spezifischen Aktivitäten von Plasma, Urin und Faeces wurden dann gemessen und daraus die Absorption sowie die endogene Calciumdurchflußgeschwindigkeit ermittelt, wozu beide in einer früheren Publikation beschriebenen Methoden benützt wurden. Die auf den Integralberechnungen der fäkalen spezifischen Aktivitäten basierenden Messungen der beiden Tracer ergaben ein befriedigenderes Resultat als jene, die auf den spezifischen Aktivitäten des Plasmas beruhten. Die Messungen an Magen-Darm-Operierten ergaben einige Hinweise auf die Lokalisation der Calciumabsorption.
Similar content being viewed by others
References
Anderson, J. B., Shimmins, J., Smith, D. A.: A new technique for the measurement of metacarpal density. Brit. J. Radiol.39, 443–450 (1966).
Bauer, G. C. H., Carlsson, A., Lindquist, B.: Evaluation of accretion, resorption and exchange reactions in the skeleton. Kungl. Fysiograf. Säll. 1 Lund Förh25, 1 (1955).
Bhandarker, S. D., Bluhm, M. M., MacGregor, J., Nordin, B. E. C.: An isotope test of calcium absorption. Brit. med. J.1961 II, 1539–1541.
Bray, G. A.: Ann. Biochem.1, 279–285 (1960).
Nordin, B. E. C., Smith, D. A.: Diagnostic procedures of calcium metabolism. London: J. A. Churchill Ltd. 1965.
Samachson, J.: Plasma values after oral45calcium and85strontium as an index of absorption. Clin. Sci.25, 17–26 (1963).
Shimmins, J., Gillespie, F. C., Orr, J. S., Smith, D. A., Alexander, W. D.: The measurement of enterie absorption rate using a double tracer technique. Advanc. Biosciences5 (1970).
Shimmins, J., Smith, D. A., Orr, J. S., Gillespie, F. C.: The measurement of calcium flow into bone. Submitted for publication.
Smith, D. A., Anderson, J. B., Shimmins, J. Speirs, C. F., Barnett, E.: Clin. Arthop. (in press).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Shimmins, J., Smith, D.A., Aitken, M. et al. The measurement of calcium absorption using an oral and intravenous tracer. Calc. Tis Res. 6, 301–315 (1970). https://doi.org/10.1007/BF02196211
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02196211