Skip to main content
Log in

Effects of humidity and light on dosimetric properties of clear polymethylmethacrylate

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Effects of humidity and light conditions /fluoroscent light, sunlight and diffuse sunlight/ on the response of 2 mm thick clear polymethylmethacrylate /PMMA/ dosimeter during irradiation and during postirradiation storage were determined spectrophotometrically at 305 and 314 nm. The results showed that irradiation of dosimeters at 12–97% relative humidity did not result in any change in the response upto 2 weeks of post-irradiation storage. However, there is some decrease in the response at higher humidities />76%/ for longer storage time. Post-irradiation storage and dosimeters at constant relative humidity conditions between 35 and 97% had no effect on the response up-to 3 weeks. Post-irradiation storage at lower relative humidity /12%/ showed some decrease in the response for longer periods. The response of dosimeter is not very sensitive to short time exposure to diffuse sunlight and fluorescent light. However, a significant increase in the optical density was observed during exposure of dosimeters to direct sunlight.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. H. Barrett, Dosimetry with dyed and undyed acrylic plastic, in Trends in Dosimetry /ed. W. L. McLaughlin/,Int. J. Appl. Radiation Isotopes, 33 /1982/ 1177.

    Article  Google Scholar 

  2. W. L. McLaughlin, Radiochromic Dye-Cyanide Dosimeters, in Manual on Radiation Dosimetry /Eds. N. W. Holm, R. J. Barry/ Marcel Dekker, New York, 1970, p. 377.

    Google Scholar 

  3. W. L. McLaughlin, Solid-phase Chemical Dosimeters, in Sterilization by Ionizing Radiation, Proc. Symp., Vienna, 1974 /Eds. E. R. L. Gaughran, A. J. Goudie/, Multiscience, Montreal, 1974, p. 219.

    Google Scholar 

  4. H. M. Khan, G. Ahmad, A. Sattar, S. K. Durrani,J. Radioanal. Nucl. Chem., 125 /1988/ 127.

    Article  Google Scholar 

  5. H. M. Khan, G. Ahmad, A. Sattar,Phys. Chem., 7 /1988/ 43.

    Google Scholar 

  6. H. Levine, W. L. McLaughlin, A. Miller,Radiat. Phys. Chem., 14 /1974/ 351.

    Google Scholar 

  7. K. Sehested, The Fricke Dosimeter, in Manual on Radiation Dosimetry /Eds. N. W. Holm, R. J. Barry/, Marcel Dekker, New York, 1970, p. 313.

    Google Scholar 

  8. A. Wexler, S. Hasegawa,J. Res. Natl. Bur. Stand., 53 /1954/ 19.

    Google Scholar 

  9. M. Ehrlich,J. Res. Natl. Bur. Stand., 65C /1961/ 203.

    Google Scholar 

  10. A. Miller, E. Bjergbakke, W. L. McLaughlin,Int. J. Appl. Radiation Isotopes, 26 /1976/ 611.

    Article  Google Scholar 

  11. K. H. Chadwick, The effect of humidity on the response of HX dosimetry perspex to radiation, in Research in Radiation Processing /IAEA-TECDOC-321/ IAEA, Vienna, 1984, p. 61.

  12. A. Miller, W. L. McLaughlin, Evaluation of radiochromic dye films and other plastic dosimeters under radiation processing conditions, in High Dose Measurements in Industrial Radiation Processing, Tech. Rep. Series No. 205, IAEA, Vienna, 1981, p. 119.

    Google Scholar 

  13. B. Whittaker, C. A. Lowe,Int. J. Appl. Radiation Isotopes, 18 /1967/ 89.

    Article  Google Scholar 

  14. K. H. Chadwick,Phys. Med. Bio., 17 /1972/ 88.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Khan, H.M., Ahmad, G. & Sattar, A. Effects of humidity and light on dosimetric properties of clear polymethylmethacrylate. Journal of Radioanalytical and Nuclear Chemistry Letters 135, 237–246 (1989). https://doi.org/10.1007/BF02164581

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02164581

Keywords

Navigation