Abstract
A method for the determination of free acidity in process solutions containing hydrolyzable ions like U(VI), Pu(IV), etc., has been developed. This method involves the titration of the free acid with electrogenerated hydroxide ions to a preset value of pH after complexing the metal ions with sodium sulfate. This method can by easily automated, requires small sample volumes and gives accurate results with good precision for samples with [UI]/[acid] mole ratios ranging from 0.25 to 16.
Similar content being viewed by others
References
E.W. Baumann, DP-1632, 1982.
M.K. Ahmed, D.S. Suryanarayana, K.N. Sabharwal, N.L. Sreenivasan,Anal. Chem., 57 (1985) 2358.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Sreenivasan, N.L., Srinivasan, T.G. A constant current coulometric method for the determination of free acidity in uranium solutions. Journal of Radioanalytical and Nuclear Chemistry Letters 176, 205–210 (1993). https://doi.org/10.1007/BF02163671
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02163671