Abstract
A purely instrumental method for the determination of Mo in uranium containing materials is presented. The precision and accuracy were verified by the analysis of several Standard Reference Materials with different proportions of Mo and U. Detection limits varied from 0.8 to 1.3 μg/g for Mo. The method can be applied to determine Mo in the studies of agricultural zone characterization.
Similar content being viewed by others
References
Z. Marczenko, R. Labinski,Pure and Appl. Chem., 63 (1991) 1627.
P. E. Cruvinel, S. Crestana, P. Artaxo, J. V. Martins, M. J. A. Armelin,Nuclear Instruments and Methods in Physics Research B, 109/110 (1996) 247.
B. Danko, R. Dybczynski,J. Radioanal. Nucl. Chem., Articles, 192 (1995) 117.
D. A. Becker, R. R. Greenberg, S. F. Stone,J. Radioanal. Nucl. Chem., Articles, 100 (1992) 41.
Wei-zhi Tian, W. D. Ehmann,J. Radioanal. Nucl. Chem., Articles, 89 (1985) 109.
J. R. W. Woittiez, M. De La Cruz Tangonan,J. Radioanal. Nucl. Chem., Articles, 158 (1992) 313.
E. Cortes Toro, R. M. Parr, S. A. Clements, Biological and environmental reference materials for trace elements, nuclides and organic microcontaminants, IAEA/RL/128 (rev. 1), Vienna, 1990.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Armelin, M.J.A., Piasentin, R.M. Instrumental neutron activation analysis for determining Mo in uranium containing materials. Journal of Radioanalytical and Nuclear Chemistry Letters 214, 509–516 (1996). https://doi.org/10.1007/BF02163565
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02163565