Abstract
A substoichiometric analytical method, using a carrier-free radioisotope, is developed for the accurate and precise determination of yttrium. The method is applied to yttrium determination in high-Tc superconducting oxide ceramics. The error of the analytical results is estimated to be within 1%.
Similar content being viewed by others
References
M.K. Wu, J.R. Ashburn, C.J. Torng, P.H. Hor, R.L. Meng, L. Gao, Z.J. Huang, Y.Q. Wang, C.W. Chu,Phys. Rev. Lett., 58 /1987/ 908.
M. Oda, T. Murakami, Y. Enomoto, M. Suzuki,J. Appl. Phys., 26 /1987/ L804.
K. Kudo, N. Suzuki,TrAC, 3 /1984/ 20.
M. Katoh, T. Shigematsu,J. Radioanal. Nucl. Chem., 102 /1986/ 149.
K. Shikano, M. Katoh, T. Shigematsu, H. Yonezawa,J. Radioanal. Nucl. Chem., Lett., /to be submitted/.
M. Katoh, T. Shigematsu, H. Yonezawa, K. Shikano, Abstracts of Papers of 47th Symp. Anal. Chem., 1986, p. 189.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Katoh, M., Shigematsu, T., Shikano, K. et al. Substoichiometric determination of yttrium in superconducting oxide ceramics by means of carrier-free radioisotope addition. Journal of Radioanalytical and Nuclear Chemistry Letters 119, 237–246 (1987). https://doi.org/10.1007/BF02162602
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02162602