Ganzkörperplethysmographie mit O2-Rückatmung und partieller CO2-Absorption

Whole-body plethysmography with O2-rebreathing and partial CO2-Absorption

  • Published:
Pneumonologie Aims and scope Submit manuscript

Abstract

Measurements with the whole-body plethysmograph are often difficult because the increasing CO2 partial pressure and the decreasing O2 partial pressure in the rebreathing bag filled with air under BTPS conditions limit the time available for the investigation. The CO2 concentration in the rebreathing system can be held at a constant level of about 3% by means of a simple technical device for CO2 absorption. This concentration is reached 20–40 breaths after the connection of the subject with the rebreathing bag filled with about 15 l pure oxygen. This prevents hypoxemia and stabilizes the ventilation of the patients as well as the conditions for the measurements in the whole-body plethysmograph.

Zusammenfassung

Die ganzkörperplethysmographischen Messungen mit einem luftgefüllten BTPS-Rückatmungsbeutel werden durch den ansteigenden CO2-Teildruck und den sinkenden O2-Teildruck zeitlich limitiert. Durch die Einfürhrung eines CO2-Absorbers ins Rückatmungssystem gelingt es, die CO2-Konzentration nach 20–40 Atemzügen konstant auf ca. 3% zu halten. Der mit ca. 15 l reinem O2 gefüllte Rückatmungsbeutel verhindert nicht nur die bei Luftatmung auftretende Hypoxämie, sondern stabilisiert auch das Atemminuten-volumen und die Meßbedingungen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Amrein, R., Keller, R., Joos, H., Herzog, H.: Neue Normalwerte für die Lungenfunktionsprüfung mit der Ganzkörperplethysmographie. Dtsch. med. Wschr.94, 1785 (1969)

    Google Scholar 

  2. Bargeton, D., Barrès, G.: Time characteristics and frequency response of body plethysmographs. Progr. Resp. Res.4, 2 (1969)

    Google Scholar 

  3. Du Bois, A. B.: Alveolar CO2 and O2 during breath holding, expiration and inspiration. J. appl. Physiol.5, 1 (1952)

    Google Scholar 

  4. Jaeger, M. J.: Die Entstehung von Schleifen im Druck-Fluß-Diagramm der Atemwege. Klin. Wschr.21, 1156 (1968)

    Google Scholar 

  5. Matthys, H.: Lungenfunktionsdiagnostik mittels Ganzkörperplethysmographie. Stuttgart-New York: Schattauer 1972

    Google Scholar 

  6. Matthys, H., Orth, U., Overrath, G., Konietzko, N.: Verhalten von Fluß, Volumen und verwandter Größen bei forcierter Atmung. Pneumonologie,147, 250 (1972)

    Google Scholar 

  7. Stanescu, D. C., De Sutter, P., Van de Woestijne, K. P.: Pressure corrected flow body plethysmograph. Amer. Rev. resp. Dis.105, 304 (1972)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gerke, E., Matthys, H. Ganzkörperplethysmographie mit O2-Rückatmung und partieller CO2-Absorption. Pneumonologie 149, 167–172 (1973). https://doi.org/10.1007/BF02151753

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02151753

Key words

Navigation