Skip to main content
Log in

Q-Switched neodymium: YAG laser surgery of the vitreous

  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract

Fifty-nine eyes underwent vitreous surgery (vitreolysis) with the Q-switched Nd:YAG laser. This was used to cut vitreoretinal bands and membranes in 16 eyes and to clear persistent vitreous opacities in 25 eyes. The use of appropriate specialized contact lenses and modification of the standard slit-lamp delivery system were essential for vitreous YAG laser surgery. Successful results occurred in eyes where the target tissues were located at distances greater than 2 mm from the crystalline lens and the retina. Vision was improved in 18 eyes, unchanged in 40 eyes, and worse in 1. Complications included focal opacities of the crystalline lens in 5 eyes, retinal holes with detachment in 1 eye, and minor retinal hemorrhages in 4. Methods of preventing complications are discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Aron-Rosa D, Aron JJ, Griesemann M, Thyzel R (1980) Use of neodymium-YAG laser to open posterior capsule after lens implant surgery. A preliminary report. J Am Intraocul Implant Soc 6:352

    PubMed  Google Scholar 

  • Bonner RF, Meyers SM, Gaasteralnd DE (1983) Threshold for retinal damage associated with the use of high-powered neodymium-YAG lasers in the vitreous. Am J Ophthalmol 96:153–159

    PubMed  Google Scholar 

  • Coherent Federal Drug Administration Pre-Market Approval Report, P830054 Approval Date July 2, 1984

  • Cohn HC, Aron-Rosa D (1983) Reopening blocked trabeculotomy sites with the YAG laser Am J Ophthalmol 95:293–294

    PubMed  Google Scholar 

  • Fankhauser F, Foussel P, Steffen J, van der Zypen E, Chrenkova A (1981) Clinical studies on the efficiency of high power laser radiation upon some structures of the anterior segment of the eye. Int Ophthalmol 3:129

    PubMed  Google Scholar 

  • Griess GA, Blankenstein MF (1980) Ocular damage from multiple pulse laser exposures. Health Phys 39:921–927

    PubMed  Google Scholar 

  • Katzen L, Fleishman JA, Trokel SL (1983) YAG laser treatment of cystoid macular edema. Am J Ophthalmol 95:293–294

    PubMed  Google Scholar 

  • Krasnov NN (1976) “Q” switched (“cool”) lasers in ophthalmology. Int Ophthalmol Clin

  • L'Esperance FA Jr (1971) Clinical photocoagulation with the frequency-doubled neodymium yttrium-aluminum-garnet (YAG) laser. Am J Ophthalmol 71:631

    PubMed  Google Scholar 

  • Schwartz PL, Fastenberg DM (1983) Retinal detachment following neodymium-YAG laser posterior capsulotomy. Presented to the Retina Society, Baltimore, Maryland, October 1, 1983 and to the American Academy of Ophthalmology, Atlanta, November 1984

  • Vassiliadis A (1966) Investigation of retinal damage using a Q-switched ruby laser. SRI Project 5571, AR Contract 33(615)-30601, Menlo Park, California, SRI, November 1966

  • Vassiliadis A, Zweng HC, Dedrick KG (1971) Ocular laser threshold investigations. Stanford Research Institute (SRI) final report for project 8209 Menlo Park, California : 3032

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Little, H.L., Jack, R.L. Q-Switched neodymium: YAG laser surgery of the vitreous. Graefe's Arch Clin Exp Ophthalmol 224, 240–246 (1986). https://doi.org/10.1007/BF02143063

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02143063

Keywords

Navigation