Summary
It is shown experimentally that the so-called delay in halogen-quenched counters is only an apparent delay. There is no real delay but only a very slow multiplication giving the impression of a delay. The secondary mechanism is assumed to be ionization of halogen molecules by metastable rare gas atoms, the latter being formed by resonance radiation. The counters used were quenched with iodine and bromine.
Similar content being viewed by others
References
Loosemore, W., and J. Sharpe, Nature167 (1951) 600.
Montgomery, C. G., and D. D. Montgomery, Rev. sci. Instr.18 (1947) 411.
Massey, H. S. W., Negative ions, Cambridge 1938.
Zoonen, D. van, and G. Prast, Appl. sci. Res.B3 (1952) 1.
Langmuir, I., and C. G. Found, Phys. Rev.36 (1930) 604.
Kruithof, A. A., and M. J. Druyvesteyn, Physica4 (1937) 450.
Kruithof, A. A., and F. M. Penning, Physica4 (1937) 430.
Townsend, J., Electrons in gases, London 1947.
Hughes, A. L., and Dixon, A. A., Phys. Rev.10 (1917) 495.
Mohler, F. L., not published. Mentioned in 11).
Mackay, C. A., Phys. Rev.24 (1924) 319.
Blewett, J. P., Phys. Rev.49 (1936) 600.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
van Zoonen, D. The delay in the build-up of halogen-quenched counters. Appl. Sci. Res. 3, 377–389 (1954). https://doi.org/10.1007/BF02123915