11. A new application tool for the ROCHE pH electrode

  • H. Henner
  • H. Rüttgers
  • D. Muliawan
  • U. Haller
  • F. Kubli
Session III: Assessment of the Design of the pH Electrode in Relation to Clinical Application
  • 41 Downloads

Summary

Using this tool the application of the pH electrode is nearly as easy as the attachment of a common ECG-scalp-electrode [3]. Visual control and lithotomy position is not necessary any more. The different tools are adapted to each other so that incision place and the tip of the pH electrode are automatically centered perpendicularly. The first results by using this tool promise to be successful. Time of application is short, the maintenance of the pH electrode is good and the application for the patient no longer disagreeable.

Key words

Fetal pH Fetal monitoring Human-tissue-pH 

Zusammenfassung

Es wird ein neues Applikationsinstrument beschrieben, durch welches die Applikation der pH-Elektrode fast ebenso leicht ist wie die Anbringung der herkömmlichen EKG-Scalp-Elektrode [3]. Visuelle Kontrolle und Steinschnittlagerung sind nicht mehr erforderlich. Die verschiedenen Teile des Applikationsinstrumentes sind aneinander so angepaßt, daß die Elektrodenspitze automatisch in die vorher angelegte Hautinzision eingeführt wird. Die ersten Ergebnisse mit diesem neuen Applikationsinstrument sind erfolgversprechend. Die Applikationszeit ist kurz, die Stabilität der pH-Elektrode ist gut und die Anwendung für den Patienten nicht mehr beschwerlich.

Schlüsselwörter

Fetus-pH-Wert Fetale Überwachung Gewebe-pH-Wert beim Menschen 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Stamm, O., Latscha, U., Janecek, P., Campana, A.: Development of a special electrode for continuous subcutaneous pH measurements in the infant scalp. Amer. J. Obstet. Gynec.124, 193 (1976)PubMedGoogle Scholar
  2. 2.
    Sturbois, G., Uzan, S., Rotten, D., Breart, G., Sureau, C.: Continuous subcutaneous pH measurement in human fetuses. Amer. J. Obstet. Gynec.128, 901 (1977)PubMedGoogle Scholar
  3. 3.
    Henner, H., Rüttgers, H., Muliawan, D., Boos, R., Kubli, F.: German Congress of perinatal medicine, Berlin, May 1977Google Scholar
  4. 4.
    Rüttgers, H., Kubli, F.: Noch eine Elektrode für die direkte fetale Elektrokardiographie sub partu. Geburtsh. Frauenheilk.31, 654 (1971)PubMedGoogle Scholar

Copyright information

© J. F. Bergmann Verlag 1978

Authors and Affiliations

  • H. Henner
    • 1
    • 2
  • H. Rüttgers
    • 1
    • 2
  • D. Muliawan
    • 1
    • 2
  • U. Haller
    • 1
    • 2
  • F. Kubli
    • 1
    • 2
  1. 1.Department of Obstetrics and Gynecology (Chairman: Prof. U. Haller, M.D.)KantonsspitalSt. GallenSwitzerland
  2. 2.Department of Obstetrics and Gynecology (Chairman: Prof. F. Kubli, M.D.)University of HeidelbergHeidelbergFederal Republic of Germany

Personalised recommendations