Skip to main content
Log in

Clinical experience with the saphena loop arteriovenous fistula on the thigh

  • Published:
International Urology and Nephrology Aims and scope Submit manuscript

Abstract

The increasing number of patients on regular dialysis treatment (RDT) for many years produces a number of problems, one of which is the vascular access procedure. When the internal subcutaneous fistula cannot be used either as the first procedure or after some years of treatment, alternative methods are necessary. We present here clinical experience with the saphenous vein arteriovenous fistula placed on the upper thigh in 8 patients. The function was insufficient with a flow rate of about 125 ml/min and the complication rate was very high with development of 5 haematomas, 1 thrombosis and 1 case of severe oedema. Far more serious, however, was the recording of 2 fatal external bleeding episodes.

According to the literature, clinical experience with this procedure is very limited in other centres. From our experience we would not recommend this procedure and from the 2 fatal bleeding episodes we would question the placement of any fistula on the upper thigh unless absolutely necessary.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Brescia, M. J., Cimino, J. E., Appel, K., Hurmich, B. J.: Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula.New Engl. J. Med., 275, 1089 (1966).

    PubMed  Google Scholar 

  2. Quinton, W. E., Dillard, D., Scribner, B. H.: Cannulation of blood vessels for prolonged hemodialysis.Trans. Am. Soc. Artif. Int. Org., 6, 104 (1960).

    Google Scholar 

  3. Enderlin, F., Harder, F., Rittmann, W. W. Massini, M. A.: Periodische Hämodialyse mit Hilfe der arterialisierten V. saphena.Helv. Chir. Acta, 38, 346 (1971).

    PubMed  Google Scholar 

  4. Lawton, R. L., Freemen, R. M.: Unusual intra- and extra-corporeal connections for vascular access.Proc. EDTA, 7, 413 (1970).

    Google Scholar 

  5. Firlit, C. F., Canning, J.: Saphenous femoral shunt.Arch. Surg., 104, 854 (1972).

    PubMed  Google Scholar 

  6. May, J., Tiller, D., Johnson, J., Stewart, J., Ros Sheil, A. G.: Saphenous-vein arteriovenous fistula in regular dialysis treatment.New Engl. J. Med., 280, 770 (1969).

    PubMed  Google Scholar 

  7. Müller-Wiefel, H.: Der subcutane arterio-venöse Shunt zur chronischen Hämodialyse.Acta Chir., 7, 7 (1972).

    Google Scholar 

  8. Harder, F., Enderlin, F.: Technical improvement in saphenous vein graft arteriovenous fistula for hemodialysis.Surg. Gynec. Obstet., 137, 1017 (1973).

    PubMed  Google Scholar 

  9. Giardet, R. E., Hackett, R. E., Goodwin, N. J., Friedman, F. A.: Thirteen months experience with the saphenous vein graft arteriovenous fistula for maintenance hemodialysis.Trans. Am. Soc. Artif. Int. Org., 16, 285 (1970).

    Google Scholar 

  10. Flores Izquierdo, G., Rondes Vivero, R.: Venous autograft for hemodialysis.Nephron, 8, 57 (1971).

    PubMed  Google Scholar 

  11. Santiago-Delpin, E. A., Buselmeir, T. J., Simmons, R. L., Najasian, J. S., Kjellstrand, C. M.: A modified saphenous vein loop-fistula in the thigh for chronic hemodialysis.Surg. Gynec. Obstet., 134, 835 (1972).

    PubMed  Google Scholar 

  12. Adar, R., Siegel, A., Bogohowsky, H., Mozes, M.: The use of arteriovenous autograft and allograft fistulas for chronic hemodialysis.Surg. Gynec. Obstet., 136, 941 (1973).

    PubMed  Google Scholar 

  13. Foran, R. F., Shore, E. N., Levin, P. M., Treiman, R. L.: Bovine heterografts for hemodialysis.West J. Med., 123, 269 (1975).

    PubMed  Google Scholar 

  14. Zerbino, V. R., Tice, D. A., Katz, L. A., Nidus, B. D.: A 6 year clinical experience with arteriovenous fistulas and bypasses for hemodialysis.Surgery, 76, 1018 (1974).

    PubMed  Google Scholar 

  15. Rolley, R. T., Sterioff, S., Williams, G. M.: Arteriovenous fistulas for dialysis using modified bovine arteries.Surg. Gynec. Obstet., 142, 700 (1976).

    PubMed  Google Scholar 

  16. Merickel, J. H., Andersen, R. C., Knutson, R., Lipschultz, M. L., Hitchcock, C. R.: Bovine carotid artery shunts in vascular access surgery.Arch. Surg., 109, 245 (1974).

    PubMed  Google Scholar 

  17. Johnson, J. M., Kenoyer, M. R., Johnson, K. E., Potter, D. J., Nichas, G. M., Williams, T.: The modified bovine heterograft in vascular access for chronic hemodialysis.Ann. Surg., 183, 62 (1976).

    PubMed  Google Scholar 

  18. Payne, J. E., Chatterjee, S. N., Barbour, B. H., Berne, T. V.: Vascular access for chronic hemodialyses using modified bovine arterial graft arteriovenous fistula.Amer. J. Surg., 128, 54 (1974).

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lynggaard, F., Nordling, J. & Hansen, R.I. Clinical experience with the saphena loop arteriovenous fistula on the thigh. International Urology and Nephrology 13, 287–290 (1981). https://doi.org/10.1007/BF02082427

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02082427

Keywords

Navigation