Observations with the double-lumen “Bi-flo” cannula in chronic intermittent haemodialysis are reported. On the evidence of urea and creatinine measurements, recirculation of blood corresponds to 7.9 and 6.1 per cent, respectively. In comparison with double-needle or single-needle dialysis, use of the double-lumen cannula does not affect the efficiency of dialysis to any notable degree.

The advantages and shortcomings of the “Bi-flo” cannula with regard to the technique of dialysis are summed up.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Boen, S. T., Haagsma-Schouten, W. A. G., Birnie, R. J.: Single needle continuous flow haemodialysis without a control module. XIVth Congress of EDTA, 1977, Abstracts p. 71.

  2. Brescia, M. J., Cimino, J. E., Appel, K., Hurwich, B. J.: Chronic haemodialysis using venipuncture and a surgical-created arterio-venous fistula.New Engl. J. Med., 275, 1089 (1966).

    PubMed  Google Scholar 

  3. Grimsrud, L.: Single puncture without auxiliary equipment.Proc. Europ. Dial. Transplant. Ass., 12, 541 (1975).

    Google Scholar 

  4. Hansen, S. K., Roden, S. M.: Double lumen single needle dialysis.Dialysis and Transplantation, 6, 45 (1977).

    Google Scholar 

  5. Karátson, A., Juhász, J., Makó, J., Tatai, J.: Single needle haemodialysis.Int. Urol. Nephrol., 8, 141 (1976).

    PubMed  Google Scholar 

  6. Kramer, P., Matthaei, D., Go, J. G., Tönnis, H. I., Scheler, F.: Dialysance of molecules of different size in reused Kiil, Ab-Gambro and Rhone-Poulenc dialysers.Brit. med. J., 2, 320 (1972).

    PubMed  Google Scholar 

  7. Kopp, K. F., Gutch, C. F., Kolff, W. J.: Single-needle dialysis.Trans. Amer. Soc. Artif. intern. Organs, 12, 75 (1972).

    Google Scholar 

  8. Tersteegen, B., van Endert, H., Schulz, D., Lagendijk, H.: Die “Bi-Flo”-Dialysekanüle.Nieren- und Hochdruckkrankheiten, 5, 2 (1976).

    Google Scholar 

  9. Twiss, E. E.: One cannula haemodialysis.Lancet, II, 1106 (1964).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Karátson, A., Farkas, L. & Frang, D. Observations with the “Bi-flo” cannula (continuous, single-needle haemodialysis). International Urology and Nephrology 11, 255–259 (1979). https://doi.org/10.1007/BF02081967

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02081967

Keywords

Navigation