Pediatric Radiology

, Volume 20, Issue 6, pp 457–460 | Cite as

Accuracy of ultrasonic bladder volume measurement in children

  • K. G. Bis
  • T. L. Slovis
Originals

Abstract

The accuracy of ultrasonography in assessing the bladder volume in 13 children with normal bladder contours was determined using the formula D x H x W (depth x height x width) with a mean error of 15.7%. This formula tends to overestimate the bladder volume in these patients. Multiplication by a correction factor of 0.9 yields a mean error of 11.5%. The accuracy of this evaluation is not dependent upon the bladder volume as the mean error was the same in those children whose bladder volume was either less than or greater than 150 cc. In addition, the accuracy of ultrasonography in assessing bladder volume was evaluated in 7 patients with an abnormal bladder contour (trabeculation, diverticula, etc.); mean error was 14.7%. In these 7 patients there was no predictable under or overestimation of bladder volume. In the children with abnormal bladder contours on ultrasound, the correction factor of 0.9 should not be used, as it does not add to the accuracy of the procedure in any individual patient. This technique is still valuable, however, in children with an abnormal bladder for it allows estimation of the extent of emptying without invasive catheterization.

Keywords

Public Health Correction Factor Volume Measurement Bladder Volume Normal Bladder 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Kiely EA, Hartnell GG, Gibson RN, Williams G (1987) Measurement of bladder volume by real-time ultrasound. Br J Urol 60:33PubMedGoogle Scholar
  2. 2.
    Harrison NW, Parks C, Sherwood T (1976) Ultrasound assessment of residual urine in children. Br J Urol 47:805Google Scholar
  3. 3.
    Rageth JC, Langer K (1982) Ultrasonic assessment of residual urine volume. Urol Res 10: 57PubMedGoogle Scholar
  4. 4.
    Alfthan O, Mattsson T (1969) Ultrasonic method of measuring residual urine. Ann Chir Gynaec Fenn 58: 300PubMedGoogle Scholar
  5. 5.
    Griffiths CJ, Murray A, Ramsden PD (1986) Accuracy and repeat ability of bladder volume measurement using ultrasonic imaging. J Urol 136: 808PubMedGoogle Scholar
  6. 6.
    Beacock CJM, Roberts EE, Rees RWM, Buck AC (1985) Ultrasound assessment of residual urin. A quantitative method. Br J Urol 57: 410PubMedGoogle Scholar
  7. 7.
    Corby VA, Heslop RA (1980) Bladder volume measurement by ultrasound. Radiography 46: 187PubMedGoogle Scholar
  8. 8.
    McLean GK, Edell SL (1978) Determination of bladder volumes by Gray Scale ultrasonography. Radiology 128: 181PubMedGoogle Scholar
  9. 9.
    Ravichandran G, Fellows GJ (1983) The accuracy of hand-held real-time ultrasound scanner for estimating bladder volume. Br J Urol 55: 25PubMedGoogle Scholar
  10. 10.
    Poston GJ, Joseph AEA, Riddle PR (1983) The accuracy of ultrasound in the measurement of changes in bladder volume. Br J Urol 55: 361PubMedGoogle Scholar
  11. 11.
    Pederson JF, Bartrum RJ, Grytten C (1975) Residual urine determination by ultrasonic scanning. AJR 125: 474Google Scholar

Copyright information

© Springer-Verlag 1990

Authors and Affiliations

  • K. G. Bis
    • 1
    • 2
  • T. L. Slovis
    • 1
    • 2
  1. 1.Departments of RadiologyChildren's Hospital of MichiganDetroitUSA
  2. 2.Wayne State University School of MedicineDetroitUSA

Personalised recommendations