Between 1985 and 1988 the use of percutaneous venous catheters in the intensive care of newborn infants was evaluated. A total of 140 polyurethane catheters used in 91 patients were compared with 143 silicone catheters in 121 neonates. Patients of both series were comparable regarding sex, weight, gestational age and severity of disease. Insertion technique, puncture site care and infusions remained the same for both observation periods. Peripheral insertion of silicone catheters required more venous cutdowns but threading them to a central vein or the right atrium was more often successful. Fewer local complications (i.e. reddening or swelling along the peripheral venous access) resulted in a longer catheter duration and a less frequent need for an additional venous access in the silicone group. On the other hand, silicone catheters caused more technical problems (i.e. rupture or obstruction). Upon removal, more silicone than polyurethane catheter tips were colonized with bacteria. This was independent of catheter duration and was never followed by clinical signs of infection. The silicone catheter gave better results, especially in very small newborn infants of low gestational age, but was associated with more technical problems.
Similar content being viewed by others
References
Allan WC, Volpe JJ (1986) Periventricular-intraventricular hemorrhage. Pediatr Clin North Am 33:47–63
Baumgart S, Hall SE, Campos JM, Polin RA (1983) Sepsis with coagulase-negative staphylococci in critically ill newborns. Am J Dis Child 137:461–463
Broviac WJ, Cole JJ, Scribner BH (1973) A silicone rubber atrial catheter for prolonged parenteral alimentation. Surg Gynecol Obstet 136:602–606
Decker MD, Edwards KM (1988) Central venous catheter infections. Pediatr Clin North Am 35:579–612
Dolcourt JL, Bose CL (1982) Percutanous insertion of silastic central venous catheters in newborn infants. Pediatrics 70: 484–486
Durand M, Ramanathan R, Martinelli B, Tolentino M (1986) Prospective evaluation of percutaneous central venous silastic catheters in newborn infants with birth weights of 510 to 3920 grams. Pediatrics 78:245–250
Loeff DS, Matlak ME, Black RE, Overall JC, Dolcourt JL, Johnson DJ (1982) Insertion of a small central venous catheter in neonates and young infants. J Pediatr Surg 17:944–948
Sadiq F, Devaskar S, Weber T, Keenan W (1985) Life threatening complications of Broviac catheterization, abstracted. Pediatr Res 19:361A
Sadiq HF, Devaskar S, Keenan WJ, Weber TR (1987) Broviac catheterization in low birth weight infants: incidence and treatment of associated complications. Crit Care Med 15:47–50
Shaw JCL (1973) Parenteral nutrition in the management of sick low birth weight infants. Pediatr Clin North Am 20:333–358
Unger A, Goetzman BW (1985) Sepsis is a major factor in late mortality of very low birth weight infants, abstracted. Pediatr Res 19:368A
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Rudin, C., Nars, P.W. A comparative study of two different percutaneous venous catheters in newborn infants. Eur J Pediatr 150, 119–124 (1990). https://doi.org/10.1007/BF02072053
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02072053