Abstract
Energy straggling in pulse height distributions of plastic scintillation counters of 4 and 10 cm in thickness was measured for 1 GeV/c pions and studied by Monte Carlo simulations. Calculated energy loss distributions are in good agreement with the experimental data and also with the prediction by the Landau straggling function.
Similar content being viewed by others
References
L. LANDAU, J. Phys. (Moscow) 8 (1944) 201.
P. V. VAVILOV, Sov. Phys. JETP, 5 (1957) 749.
P. SHULEK, B. M. GOLOVIN, L. A. KULYUKINA, S. V. MEDVED', P. PAVLOVICH, Sov. J. Nucl. Phys., 4 (1967) 400.
H. BICHSEL, R. P. SAXON, Phys. Rev. A11 (1975) 1286.
J. H. COBB, W. W. ALLISON, J. N. BUNCH, Nucl. Instr. Meth., 133 (1976) 315.
F. HARRIS et al., Nucl. Instr. Meth., 107 (1973) 413.
H. ESBERG et al., Phys. Rev., B18 (1978) 1039.
S. HANCOCK, F. JAMES, J. MOVCHET, P. G. RANCOITA, L. VANROSSAM, Phys. Rev., A28 (1983) 615.
Y. TSUJITA et al., submitted for publication.
D. M. RITSON, Technique of High Energy Physics, D. M. RITSON (Ed.), Interscience Publishers, Inc., New York, 1961, Chapter I.
K. S. KOLBIG, B. SCHORR, Comp. Phys. Comm., 31 (1984) 97.
R. M. STERNHEIMER, Phys. Rev., 88 (1952) 851.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Asano, Y., Hamasaki, H., Mori, S. et al. Energy straggling of 1 GeV/c negative pions in plastic scintillation counters of 4 and 10 cm in thickness. Journal of Radioanalytical and Nuclear Chemistry Articles 210, 79–85 (1996). https://doi.org/10.1007/BF02055408
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02055408