Skip to main content
Log in

Verification testing of commercially available computer programs for photopeak area evaluation

The influence of peak width

  • Specialized Radioanalytical Methods
  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Computer programs available from three major manufacturers of systems for γ-ray spectrometry were tested by measuring the same152Eu source under nearly identical conditions. Results for the evaluation of peaks with full widths at half maximum ranging from less than 3 and up to 15 channels were compared with those obtained by a reference program based on peak integration using optimum peak boundary selection. Two out of three commercial programs produced results without significant influence of peak width, but none of them could maintain the same level of statistical control throughout the range of interest that the reference program does.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. R. M. PARR, H. HOUTERMANS, K. SCHAERF, Computers in Activation Analysis and Gamma-Ray Spectroscopy, U.S. Department of Energy, Symposium Series 49, 1979, p. 544.

    Google Scholar 

  2. K. HEYDORN, Computers in Activation Analysis and Gamma-Ray Spectroscopy, U.S. Department of Energy, Symposium Series 49, 1979, p. 85.

    Google Scholar 

  3. K. HEYDORN, Nuclear Methods in Environmental and Energy Research, U.S. Department of Energy, CONF-840408, 1985, p. 620.

  4. L. MOENS, F. De CORTE, A. De WISPELAERE, J. HOSTE, A. SIMONITS, A. ELEK, J. SZABÓ, J. Radioanal. Nucl. Chem., 82 (1984) 385.

    Article  Google Scholar 

  5. K. HEYDORN, W. LADA, Anal. Chem., 44 (1972) 2313.

    Article  Google Scholar 

  6. K. HEYDORN, Neutron Activation Analysis for Clinical Trace Element Research Vol. 1, CRC Press, Boca Raton, 1984, p. 152.

    Google Scholar 

  7. Nuclear Data Inc., ID6600 Peak Search Program Algorithm, ND-604A. Schaumburg, 1980.

  8. L. H. CHRISTENSEN, K. HEYDORN, 7th Intern. Conf. Modern Trends in Activation Analysis, Vol. 1, Isotope Division, Risø National Laboratory, 1986, p. 551.

    Google Scholar 

  9. EG&G Ortec, GELIGAM Software Module, A30-B1, Oak Ridge, 1985.

  10. P. A. AARNIO, J. T. ROUTTI, J. V. SANDBERG, Micro SAMPO Version 1.0, April 1986.

  11. J. T. ROUTTI, S. G. PRUSSIN, Nucl. Instrum. Methods, 72 (1969) 125.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Heydorn, K., Christensen, L.H. Verification testing of commercially available computer programs for photopeak area evaluation. Journal of Radioanalytical and Nuclear Chemistry, Articles 124, 467–480 (1988). https://doi.org/10.1007/BF02041337

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02041337

Keywords

Navigation