Skip to main content
Log in

Anticosmic-shielded ultralow-background germanium detector systems for analysis of bulk environmental samples

  • Specialized Radioanalytical Methods
  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

A low-level gamma-ray counting system has been developed which reduces system background, relative to other typical low-background systems, by a factor of ten in the energy region below one MeV, and by as much as a factor of forty at higher energies. This germanium-diode gamma-ray spectrometer was constructed for a modest investment above that required for a conventional germanium detector. The techniques involved use: (1) materials of known radiopurity to surround the diode, (2) an active external anticosmic shield to reduce the background continuum due to interactions of cosmic particles with the detector and passive lead shielding, and (3) nitrogen exhausted from the cryogenic dewar to minimize the introduction of ubiquitous radon decay nuclei into the sample counting chamber. A novel method for handling samples prior to counting is presented. Also; some of the difficulties encountered in calibrating a system intended for bulk samples are discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. W. H. ZIMMER, S. E. WAGNER, Nucl. Instrum. Methods Phys. Res., 223 (1984) 412.

    Article  Google Scholar 

  2. H. L. MALM, N. M. WATT, Nucl. Instrum. Methods Phys. Res., 223 (1984) 420.

    Article  Google Scholar 

  3. J. H. REEVES, W. K. HENSLEY, R. L. BRODZINSKI, P. RYGE, IEEE Trans. Nucl. Sci., NS-31 (1984) No. 1, 697.

    Google Scholar 

  4. K. S. PARTHASARATHY, Nucl. Instrum. Methods, 136 (1976) 585.

    Article  Google Scholar 

  5. R. L. BRODZINSKI, J. H. REEVES, F. T. AVIGNONE, H. S. MILEY, Nucl. Instrum. Methods Phys. Res., A254 (1987) 472.

    Google Scholar 

  6. G. HEUSSER, Nucl. Instrum. Methods Phys. Res., B17 (1986) 418.

    Google Scholar 

  7. G. HEUSSER, Nucl. Instrum. Methods Phys. Res., B17 (1986) 423.

    Google Scholar 

  8. P. RIZZACASA, Nucl. Instrum. Methods Phys. Res., B17 (1986) 519.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Operated for the U.S. Department of Energy by Battelle Memorial Institute under Contract DE-AC06-76RLO 1830.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Reeves, J.H., Arthur, R.J. Anticosmic-shielded ultralow-background germanium detector systems for analysis of bulk environmental samples. Journal of Radioanalytical and Nuclear Chemistry, Articles 124, 435–447 (1988). https://doi.org/10.1007/BF02041334

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02041334

Keywords

Navigation