Abstract
A simple, low cost TLC scanner system for the characterization of γ-emitting radiopharmaceuticals is described. The TLC γ scanner has a linear response range of ∼0.074 Mbq up to ≥2.94 Mbq. The accuracy and reproducibility of measurement is better than ±5% (relative). The utility of this TLC scanner system is demonstrated by application to the radioanalytical evaluation of99mTc(dmpe)2Cl +2 preparations. A comparison with HPLC radioanalytical separations is made.
Similar content being viewed by others
References
G. ZWEIG, J. SHERMA, Anal. Chem., 52 (1980) 276R.
H. J. ISSAG, J. Liq. Chrom., 4 (1981) 955.
H. J. ISSAG, J. Liq. Chrom., 3 (1980) 1435.
HPTLC; A. ZLATKIS, R. E. KAISER, (Eds), Elsevier, Amsterdam, The Netherlands; 1977.
G. GUICHON, F. BRESSABLE, A. SIOUFFI, J. Chrom. Sci., 17 (1979) 368.
M. PROSEK, A. MEDJA, E. KUCAN, M. KATIC, M. BANO, J. HRC and CC, 2 (1979) 517.
D. JÄNCHEN, H. R. SCHMUTZ, J. HRC and CC; 1 (1979) 133.
K. A. KROHN, A. L. JANSHALT, Int. J. Appl. Radiation Isotopes, 28 (1977) 213.
R. E. BISH, D. SILVERSTEIN, J. I. BEDE, J. Radioanal. Chem., 57 (1980) 565.
USP XX, The United States Pharmacopeia, National Formulary NF XV, 1980, p. 762.
P. J. ROBBINS, Chromatography of Technetium-99m Radiopharmaceuticals—A Practical Guide; Society of Nuc. Med. Publishers; N. Y., N. Y., 1983, p. 35.
T. PINKERTON, D. FERGUSON, E. DEUTSCH, W. R. HEINEMAN, K. LIBSON, Int. J. Appl. Radiation Isotopes 33 (1982) 907.
S. C. SRIVASTAVA, D. BANDYOPADHYAY, G. MEINKEN, P. RICHARDS, 28th Society of Nuclear Medicine meeting abstracts, 1981.
A. NUNN, J. Chrom., 255 (1983) 91.
M. D. LOBERG, A. D. NUNN, D. W. PORTER, in Nuclear Medicine Annual, L. M. FREEMAN, H. S. WEISSMAN, (Eds), Raven Press Publications; New York; 1981.
A. R. FRITZBERG, D. LEWIS, J. Nucl. Med., 21 (1980) 1180.
E. DEUTSCH, J. Nuc. Med., 23 (1982) 1093.
A. L. JANSHOLT, K. A. KROHN, D. R. VERA, H. H. HINES, J. Nuc. Med. Tech., 8 (1980) 222.
B. L. KARGER, L. R. SNYDER, C. HORVATH, An Introduction to Separation Science, Wiley Interscience Publication, John Wiley & Sons New York, New York, 1973, p. 149.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Carpenter, A.P., Mysliwy, T.J., Sivakoff, S.I. et al. Characterization and use of a gamma radiation TLC scanner for radiochemical purity measurements of radiopharmaceutical kit preparations of99mTc(dmpe)2Cl +2 . Journal of Radioanalytical and Nuclear Chemistry, Articles 89, 435–446 (1985). https://doi.org/10.1007/BF02040607
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02040607