Abstract
A method for the sequential determination of thorium and uranium has been developed. In the sample solution containing thorium and uranium, thorium is first determined by complexometric titration with ethylenediaminetetraacetic acid (EDTA) and then in the same solution uranium is determined by redox titration employing potentiometry. As EDTA interferes in uranium determination giving positive bias, it is destroyed by fuming with HClO4 prior to the determination of uranium. A precision and accuracy of better than ±0.15% is obtained for thorium at 10mg level and uranium ranging from 5 mg to 20 mg in the aliquot.
Similar content being viewed by others
References
Selected Measurement Methods for Plutonium and Uranium in Nuclear Fuel Cycle, C. J. RODDEN (Ed.), 2nd ed., USAEC Report, TID-7029, 1972.
S. P. HASILKAR, N. GOPINATH, KESHAV CHANDER, S. G. MARATHE, H. C. JAIN, J. Radioanal. Nucl. Chem., 122 (1988) 69.
A. R. EBERLE, M. W. LERNER, C. G. GOLDBECK, C. J. RODDEN, Report, NBL-252, 1970.
M. JOHN, S. VAIDYANATHAN, P. VENKATARAMAN, P. R. NATARAJAN, Convention of Chemists, Bangalore 1976; Report, BARC/I-634, 1981.
S. G. MARATHE, B. N. PATIL, VEENA BHANDIWAD, KESHAV CHANDER, Talanta, 30 (1983) 151.
S. P. HASILKAR, KESHAV CHANDER, S. G. MARATHE, J. Radioanal. Nucl. Chem., 139 (1990) 263.
S. G. MARATHE, N. REGHU, KESHAV CHANDER, P. R. NATARAJAN, Fresen. Z. Anal. Chem., 321 (1985) 597.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Chander, K., Hasilkar, S.P., Jadhav, A.V. et al. A titrimetric method for the sequential determination of thorium and uranium. Journal of Radioanalytical and Nuclear Chemistry, Articles 174, 127–132 (1993). https://doi.org/10.1007/BF02040340
Received:
Issue Date: