Skip to main content
Log in

Count rate effects in analysis programs using fitting techniques

  • Counting System
  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

This work discusses the relative merits of parabolic, linear, or step background functions under the photopeak in a SAMPO type fitting algorithm used in the Canberra APOGEE package for a PDP-11 or a VAX-11 minicomputer. Four different variations of the background are subjected to a statistical test of precision under stable measurement conditions and investigated for their behavior as a function of count rate.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. T. ROUTTI, S. G. PRUSSIN, Nucl. Instr. Methods, 72 (1969) 125.

    Article  Google Scholar 

  2. H. H. JORCH, J. L. CAMPBELL, Nucl. Instr. Methods, 143 (1977) 551.

    Article  Google Scholar 

  3. R. G. HELMER, M. A. LEE, Nucl. Instr. Methods, 178 (1980) 499.

    Article  Google Scholar 

  4. R. GUNNINK, in: Computers in Activation Analysis and Gamma-Ray Spectroscopy, Proc. Conf. at Mayaguez, Puerto Rico, 1978 (1979), p. 109.

  5. W. WATZIG, in: Computers in Activation Analysis and Gamma-Ray Spectroscopy, Proc. Conf. at Mayaguez, Puerto Rico, 1978 (1979), p. 150.

  6. R. M. PARR, H. HOUTERMANS, K. SCHAERF, in: Computers in Activation Analysis and Gamma-Ray Spectroscopy, Proc. Conf. at Mayaguez, Puerto Rico, 1978 (1979), p. 544.

  7. S. G. PRUSSIN, Nucl. Instr. Methods, 193 (1982) 121.

    Article  Google Scholar 

  8. M. J. KOSKELO, J. SIEFERT, in: Computer Applications in Health Physics, Proc. 17th Midyear Topical Symposium of Health Physics Society, Pasco, Washington, 1984, Session 4.27.

  9. M. J. KOSKELO, P. A. AARNIO, J. T. ROUTTI, Nucl. Instr. Methods, 190 (1981) 89.

    Article  Google Scholar 

  10. M. J. KOSKELO, J. Radioanal. Chem., 70 (1982) 473.

    Google Scholar 

  11. K. HEYDORN, in: Computers in Activation Analysis and Gamma-Ray Spectroscopy, Proc. Conf. at Mayaguez, Puerto Rico, 1978 (1979), p. 85.

  12. J. A. JACKMAN, I. K. MacKENZIE, J. L. CAMPBELL, H. H. JORCH, Nucl. Instr. Methods, 172 (1980) 583.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Koskelo, M.J. Count rate effects in analysis programs using fitting techniques. Journal of Radioanalytical and Nuclear Chemistry, Articles 114, 215–221 (1987). https://doi.org/10.1007/BF02039794

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02039794

Keywords

Navigation