Skip to main content
Log in

The development of a rectilinear scanner utilizing high resolution gamma-ray detection

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

A rectilinear scanner has been constructed which incorporates high resolution gamma-ray spectroscopy. This scanner was built to simultaneously image the distributions of multiple gamma-emitting radionuclides in small animals, such as rabbits and rats. The instrument design is described, followed by studies of the Ge(Li) detector response and calibration tests of a single straight-hole collimator. Based on these results, two new collimators were designed and constructed; (1) a six tapered-hole focusing collimator and (2) a nine straight-hole focusing collimator. These new collimators are advantageous because they offer an increased efficiency of gamma-ray detection during scanning. They also give better image resolution in the differentiation of two points (or organs) on a plane. The results of the calibration tests and comparisons of the resolution and efficiency among collimators are illustrated and discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. A. SORENSON, M. E. PHELPS, Physics in Nuclear Medicine, W. B. Saunders Company, Philadelphia, 1987, Chapters 16–17.

    Google Scholar 

  2. R. F. JOHNSON, Operation and Ouality Control of the Rectilinear Scanner, C. V. Mosby Corporation, St. Louis, 1977, Chapter 9.

    Google Scholar 

  3. A. V. OPPENHEIM, A. S. WILSKY, Signals and Systems, Englewood Cliffs, Inc., New Jersey, 1983, Chapter 8.

    Google Scholar 

  4. C. M. LEDERER, V. S. SHIRLEY, Table of Isotopes, Lawrence Berkeley Laboratory, University of California, John Wiley and Sons, Inc., New York, 1978.

    Google Scholar 

  5. W. McC. SIEBERT, Circuits, Signals, and Systems, McGraw-Hill Book Company, New York, 1986, Chapter 14.

    Google Scholar 

  6. J. C. EHRHARDT, L. W. OBERLY, J. M. CUERAS, Imaging Ability of Collimators in Nuclear Medicine, Rockville, Maryland., U. S. Dept. H. E. W., 1978.

    Google Scholar 

  7. T. N. PADIKAL, S. P. FIVOZINSKY, Medical Physics Data Book, NBS Handbook 138, Washington, D. C., 1982, p. 48.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zinn, K.R., Morris, J.S., Fairfax, C.A. et al. The development of a rectilinear scanner utilizing high resolution gamma-ray detection. Journal of Radioanalytical and Nuclear Chemistry, Articles 157, 15–25 (1992). https://doi.org/10.1007/BF02039773

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02039773

Keywords

Navigation