Abstract
90Y is coupled through DTPA chelator in Mab B72.3 antibody with good radiochemical yield. The process of labelling is relatively fast (30 min). Care must be taken on parameters of quality control, because they influence the results. The difference was 1.5 time between the analysis performed at the 1st and the 12th minutes after mixing labelled antibody with DTPA.
References
D. J. Hnatovich et al., J. Nucl. Med., 26 (1985) 503.
Y. A. Roger et al., Radionuclides for therapy: A Review, Proc. 4th Bottstein Colloquium on the Use of Radionuclies and Vehicles for Tumour Therapy, 13–14 June 1986.
Oncoscint: An advance in the detection and management of colorectal carcinoma, Eurocetus ed., 1991.
S. Malja, K. Schomäcker. Some aspects of the90Sr-90Y generator production. BPU-2 Congress, Izmir, 1994.
A. M. Zimmer et al., Nucl. Med. Biol., 15 (1986) 717.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Malja, S., Schomäcker, K. & Damani, G. Preliminary results on labelling antibody Mab B72.3 with90Y. J Radioanal Nucl Chem 218, 255–257 (1997). https://doi.org/10.1007/BF02039346