Abstract
A sensitive radiochemical procedure has been developed for the separation and determination of Dy, Sm, Gd, Eu, La and Lu in high purity uranium. The method is based on quantitative extraction of uranium using NPy/benzene as an extractant from 7M HCl solution. Rare earth elements (REE) remaining in the aqueous phase were subsequently determined by INAA.
Similar content being viewed by others
References
S. DE MORAES, A. ABRAO., Anal. Chem., 46 (1974) 1812.
A. TOLK, V. RAAPHORST, IAEA-SM-1491/12 (1974) 184.
I. P. ALIMARIN, A. Z. MILKISHANSKI, Y. V. YAKOVELI, J. Radioanal. Chem., 4 (1970) 45.
S. AHMAD, M. S. CHAUDHRY, I. H. QURESHI, J. Radioanal. Chem., 57 (1980) 185.
M. EJAZ, Separation Sci., 13 (1978) 843.
G. ERDTMAN, W. SOYKA, Die Linie der Radionuklide Band (IoIIoIII) KFA, Julich, Germany. Jul-1003-AC (1974)
R. SHER, Handbook on Nuclear Cross Section, Vol. I, IAEA, Rep. Ser. No 156,(1974)
S. AHMAD, M. S. CHAUDHRY, I. H. QURESHI J. Radioanal. Chem., 67 (1981) 119.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ahmad, S., Chaudhry, M.S. & Qureshi, I.H. Determination of rare earth elements impurities in high purity uranium. Journal of Radioanalytical and Nuclear Chemistry, Articles 83, 201–208 (1984). https://doi.org/10.1007/BF02037133
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02037133