Characterisation of mixed radiation field produced in medical linear accelerators using foil activation technique

  • Other Nuclear and Related Techniques
  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

The photon spectrum produced in medical linear accelerators and used for tumour therapy was measured using foil activation techniques in this work. The machine employed is the linear medical accelerator SL-25, Philips, installed at the Walsgrave Hospital Radiotherapy Centre in Coventry, U.K. A number of foil sets, with different energy thresholds were irradiated at different points inside a 400 mm by 400 mm treatment field at a nominal dose rate of 400 MU (∼4 Gy/min), and photon energy of 25 MV at the machine's isocentre. The induced activity of each foil was measured using a NaI(Tl) detector and a PC-based multichannel analyzer. The spectrum of the photons was unfolded using the computer code LOUHI82. The relative changes in the spectrum across the treatment field, were also measured using foils placed at 2.5°, 5°, 10° and 13° on both sides of the central axis of the treatment field. In order to estimate the extra dose received by the patient due to the neutron component, the neutron flux distribution at different points across the treatment field was measured using gold foils. The results and implications are discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P. H. Huang, K. R. Kase, B. E. Bjarngard, Med. Phys., 8 (1981) 368.

    PubMed  Google Scholar 

  2. P. H. Huang, K. R. Kase, B. E. BJarngard, Med. Phys., 9 (1982) 695.

    PubMed  Google Scholar 

  3. C. R. Baker, B. Ama'ee, N. M. Spyrou, Phys. Med. Biol., 40 (1995) 529.

    PubMed  Google Scholar 

  4. B. R. Archer, P. R. Almond, L. K. Wagner, Med. Phys., 12 (1985) 630.

    PubMed  Google Scholar 

  5. G. E. Desobry, A. L. Boyer, Med. Phys., 18(3) (1991) 497.

    PubMed  Google Scholar 

  6. L. B. Levy, R. Waggener, W. D. McDavid, W. H. Payne, Med. Phys., 1 (1974) 62.

    PubMed  Google Scholar 

  7. H. Hirayama, T. Nakamura, Nucl. Sci. Eng., 50 (1973) 248.

    Google Scholar 

  8. R. Nath, R. J. Schulz, Med. Phys., 3 (1976) 133.

    PubMed  Google Scholar 

  9. National Council on Radiation Protection and Measurement, Report No. 79, 1984.

  10. S. S. Dietrich, B. L. Berman, Atomic Data and Nuclear Data Tables, 38 (1988) 199.

    Google Scholar 

  11. L. Moens, J. Hoste, Int. J. App. Rad. Isot., 34 (1983) 1085.

    Google Scholar 

  12. J. T. Routti, J. V. Sandberg, Comput. Phys. Commun., 21 (1980) 119.

    Google Scholar 

  13. J. V. Sandberg, J. T. Routti, Nucl. Tech., 63 (1981) 83.

    Google Scholar 

  14. W. N. McPlroy, S. Berg, T. Crockett, R. G. Hawkins, Report AFWL-TR-67-47, U.S. Air Force 1967.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Assatel, O.Z., Spyrou, N.M. Characterisation of mixed radiation field produced in medical linear accelerators using foil activation technique. J Radioanal Nucl Chem 217, 255–260 (1997). https://doi.org/10.1007/BF02034452

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02034452

Keywords

Navigation