Journal of Clinical Monitoring

, Volume 12, Issue 1, pp 27–33 | Cite as

Blood glucose reagent strip tests in the operating room: Influence of hematocrit, partial pressure of oxygen, and blood glucose level - a comparison of the BM-test 1-44, BM-accutest, and satellite G reagent strip systems

  • Michael Hugh Cross
  • David G. Brown
Original Articles

Abstract

Objective. The objective of our study was to assess the influence of hematocrit (HCT), partial pressure of oxygen (PO2), and blood glucose level upon results obtained with three different blood glucose reagent strip tests used in conjunction with the appropriate meter: BM-Test 1-44, BM-Accutest, and Satellite G.Methods. Our study was designed as a consecutive sample study of patients undergoing coronary artery surgery. The setting was the hospital theater and intensive care unit. We conducted blood analysis for HCT, PO2 and blood glucose on 20 consecutive patients undergoing coronary artery surgery using three blood glucose reagent strip testing systems and a laboratory analysis of plasma glucose.Results. All three blood glucose reagent strip tests showed a significant bias when compared with plasma glucose: BM-Test 1-44, 0.89 mmol/L; BM-Accutest, −1.27 mmol/L; Satellite G, 0.75 mmol/L (p < 0.05). The error found when using the Satellite G system was worse than that of either of the other two systems. Results obtained with the BM-Accutest strips were unaffected by PO2 (p = 0.745). Blood glucose value and HCT both had an influence on the results of all three blood glucose strip systems.Conclusions. Caution must be taken when using reagent strip systems in the operating room or intensive care setting because, of the three systems tested, all showed a significant bias, all were influenced by blood glucose level and HCT, and only the BM-Accutest reagent strips used with the Accutrend meter was unaffected by PO2.

Key words

Measurement: blood glucose Hematocrit Oxygen Reagent strip 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Stick testing (Editorial). Br Med J 1991; 302: 482–483Google Scholar
  2. 2.
    Weiner K. The effect of haematocrit on reagent strip tests for glucose. Diabetic Med 1991; 8: 172–175CrossRefGoogle Scholar
  3. 3.
    Trinder P. Determination of glucose in blood using glucose oxidase with an alternative oxygen acceptor. Ann Clin Biochem 1969; 6: 24Google Scholar
  4. 4.
    Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1(8476): 307–310PubMedGoogle Scholar
  5. 5.
    Tietz NW, ed. Textbook of clinical chemistry. Philadelphia: Saunders, 1986Google Scholar
  6. 6.
    Morrison B, Fleck A. Plasma or whole blood glucose. Clinica Chemica Acta 1973; 45: 293–297CrossRefGoogle Scholar
  7. 7.
    Consensus Development Panel. Consensus statement on self-monitoring of blood glucose. Diabetes Care 1987; 10: 95–99Google Scholar
  8. 8.
    Koschinsky T, Dannehl K, Gries FA. New approach to technical and clinical evaluation of devices for self-monitoring of blood glucose. Diabetes Care 1988; 11: 619–629PubMedCrossRefGoogle Scholar
  9. 9.
    Smith LA, McNaught J, Hutchinson AS. How well do nurses perform blood glucose analyses at the diabetic clinic? An assessment using the Reflotron analyzer. Ann Clin Biochem 1990; 27: 156–157PubMedGoogle Scholar
  10. 10.
    Sieber FE, Traystman RJ. Special issues: Glucose and the brain. Crit Care Med 1992; 20: 104–114PubMedCrossRefGoogle Scholar
  11. 11.
    Brooks KE, Rawal N, Henderson AR. Laboratory assessment of three new monitors of blood glucose. Clin Chem 1986; 32: 2195–2200PubMedGoogle Scholar
  12. 12.
    Weiner K. Whole blood glucose: What are we measuring? Ann Clin Biochem 1995; 32: 1–8Google Scholar

Copyright information

© Kluwer Academic Publishers 1996

Authors and Affiliations

  • Michael Hugh Cross
    • 1
  • David G. Brown
    • 2
  1. 1.Department of AnaesthesiaThe General Infirmary at LeedsLeedsEngland
  2. 2.Department of Chemical Pathology and ImmunologyThe General Infirmary at LeedsLeedsEngland

Personalised recommendations