We have developed a simple system for internal validation of oximetry data collected over many hours from the Nellcor N-200 pulse oximeter (Nellcor, Inc., Hayward, CA). This system uses signals from the oximeter alone and a validation algorithm that is based in a computer connected to the oximeter. Unlike other validation systems, this system does not require connections to other monitors. The system was tested on 10 acutely ill newborns in an intensive care nursery over 16 hr of continuous recording for each infant (birthweight, 2.50±0.73 kg; age, 3.4±3.2 days). Oximetry data were accepted as valid using the new system if they surpassed a minimum level of quality (empirically derived, and equal to a 60% fractional success in pulse detection). The validated oximetry data were compared to data obtained using a conventional “compared to the electrocardiogram (ECG)” algorithm. For the new and the conventional algorithms, the distributions of validated SpO2 percents were nearly identical, with data rejection rates of 28.9% for the new system and 37.3% for the conventional system. In the newborns, the new system was used to demonstrate that as the mean saturations decreased, there were striking increases in variability about the reported mean saturation (p < 0.001). While variability in infant SpO2 is a well-known phenomenon, the amount seen here was unexpected. For example, the range of true saturations frequently recorded was quite wide at a reported mean SpO2 of 90% (from 81 to 94%; but, the range was only from 92 to 98% at a mean SpO2 of 96%). These findings demonstrate the usefulness of the new system and, if substantiated in more detailed studies, have important implications for the use of pulse oximeters to assess oxygenation in newborns.
Article PDF
Similar content being viewed by others
References
Phelps DL. Retinopathy of prematurity. Pediatr Clin North Am 1993; 40: 705–714
Tay-Uyboco JS, Kwiatkowski K, Cates DB, et al. Hypoxic airway constriction in infants of very low birth weight recovering from moderate to severe bronchopulmonary dysplasia. J Pediatr 1989; 115: 456–459
Moss AF, Emmanouilides GC, Adams FH, Chuang K. Response of ductus arteriosus and pulmonary and systemic arterial pressures to changes in oxygen environment in the newborn infant. Pediatrics 1964; 33: 937–944
deLemos RA, Coalson JJ. The contribution of experimental models to our understanding of the pathogenesis and treatment of bronchopulmonary dysplasia. Clin Perinatol 1992; 19: 521–539
Hay WW, Thilo E, Curlander JB. Pulse oximetry in neonatal medicine. Clin Perinatol 1991; 18: 441–472
Durand M, Evoy C, MacDonald K. Spontaneous desaturations in intubated very low birth weight infants with acute and chronic lung disease. Pediatr Pulmonol 1992; 13: 136–142
Reynolds GJ, Yu VYH. Guidelines for the use of pulse oximetry in the non-invasive estimation of oxygen saturation in oxygen-dependent newborn infants. Aust Paediatr J 1988; 24: 346–350
Jones RDM, Lawson AD, Gunawardene WMS, et al. An evaluation of prolonged course oximetry data acquisition. Anaesth Intens Care 1992; 20: 303–307
Garg M, Kurzner SI, Bautista DB, Keens TG. Clinically unsuspected hypoxia during sleep and feeding in infants with bronchopulmonary dysplasia. Pediatrics 1988; 81: 635–642
Singer L, Martin RJ, Hawkins SW, et al. Oxygen desaturation complicates feeding with bronchopulmonary dysplasia after discharge. Pediatrics 1992; 90: 380–384
Schwid HA, Olson C, Wright P, Freund PR. Microcomputer-based data acquisition system for clinical research. J Clin Monit 1990; 6: 141–146
Nellcor Inc. Operator's manual. Nellcor N-200 pulse oximeter. Hayward, CA: Nellcor Inc, 1991: 29–37
Gofton PW. Mastering serial communications. San Francisco: SYBEX, 1986: 11–13
Gravenstein JS, deVries A, Beneken JEW. Sampling intervals for clinical monitoring of variables during anesthesia. J Clin Monit 1989; 5: 17–21
Ralston AC, Webb RK, Runciman WB. Potential errors in pulse oximetry. Anaesthesia 1991; 46: 291–295
Severinghaus JW, Naifeh KH, Koh SO. Errors in 14 pulse oximeters during profound hypoxia. J Clin Monit 1989; 5: 72–81
Poets CF, Southall DP. Noninvasive monitoring of oxygenation in infants and children: Practical considerations and areas of concern. Pediatrics 1994; 93: 737–746
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Sprague, D., Richardson, M.S., Baish, J.W. et al. A new system to record reliable pulse oximetry data from the nellcor N-200 and its applications in studies of variability in infant oxygenation. J Clin Monitor Comput 12, 17–25 (1996). https://doi.org/10.1007/BF02025306
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02025306