Skip to main content
Log in

Comparison of a simplified liquid chromatographic assay of gentamicin in serum with enzyme immunoassay and bioassay

  • Original Articles
  • Published:
European Journal of Clinical Microbiology Aims and scope Submit manuscript

Abstract

A sensitive and reproducible high-performance liquid chromatographic (HPLC) method is described for assay of gentamicin in serum using ultrafiltration of serum samples and pre-column derivatization with o-phthalaldehyde. The procedure was compared with a bioassay and an enzyme immunoassay. Coefficients of correlation were 0.98 for HPLC vs. bioassay and 0.97 for HPLC vs. immunoassay. The between-day imprecision (n=5) was estimated from the coefficients of variation at a concentration of 6 mg/l. Values were 9.4 % for the bioassay, 6.5 % for the immunoassay and 2.4 % for the chromatographic method. The major advantage of the method described is simplified sample preparation and optimal serum extraction. The latter is important in routine use because it prolongs column life and thus reduces costs.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Lund, M. E., Blazevic, J. D., Matsen, J. M.: Rapid gentamicin bioassay using a multiple-antibiotic-resistant strain ofKlebsiella pneumoniae. Antimicrobial Agents and Chemotherapy 1973, 4: 569–573.

    PubMed  Google Scholar 

  2. Urban, T., Jarstrand, C.: Rapid micromethod for aminoglycoside assay in serum by utilization of bacterial reduction of nitroblue tetrazolium. Journal of Antimicrobial Chemotherapy 1980, 6: 357–361.

    PubMed  Google Scholar 

  3. Watson, R. A. A., Landon, J., Edwards, C. R. W., Shaw, E. J.: Improved125I-ligands for gentamicin radioimmunoassay. Journal of Antimicrobial Chemotherapy 1979, 5: 673–680.

    PubMed  Google Scholar 

  4. Meulemans, A., Manuel, C., Tran Ba Huy, P.: Radioimmunoassay of gentamicin in microliter and nanoliter samples of biological fluids. Chemotherapy 1981, 27: 29–33.

    PubMed  Google Scholar 

  5. Shaw, E. J., Watson, R. A. A., Landon, J., Smith, D. S.: Estimation of serum gentamicin by quenching fluoroimmunoassay. Journal of Clinical Pathology 1977, 30: 526–531.

    PubMed  Google Scholar 

  6. Burd, J. F., Wong, R. C., Feeny, J. E., Carrico, R. J., Boguslaski, R. C.: Homogeneous reactant-labeled fluorescent immunoassay for therapeutic drugs exemplified by gentamicin determination in human serum. Clinical Chemistry 1977, 23: 1402–1408.

    PubMed  Google Scholar 

  7. Kabakoff, D. S., Leung, D. K., Singh, P.: An EMIT assay for gentamicin. Clinical Chemistry 1978, 24: 1055.

    Google Scholar 

  8. O'Leary, T. D., Ratcliff, R. M., Geary, T. D.: Evaluation of an enzyme immunoassay for serum gentamicin. Antimicrobial Agents and Chemotherapy 1980, 17: 776–778.

    PubMed  Google Scholar 

  9. Mayhew, J. W., Gorbach, S. L.: Assay of gentamicin and tobramicin in sera of patients by gas-liquid chromatography. Antimicrobial Agents and Chemotherapy 1978, 14: 851–855.

    PubMed  Google Scholar 

  10. Maitra, S. K., Yoshikawa, Th. T., Hansen, J. L., Nilsson-Ehle, I., Palin, W. J., Schotz, M. C., Guze, L. B.: Serum gentamicin assay by high-performance liquid chromatography. Clinical Chemistry 1977, 23: 2275–2278.

    PubMed  Google Scholar 

  11. Anhalt, J. P., Brown, St. D.: High-performance liquid-chromatographic assay of aminoglycoside antibiotics in serum. Clinical Chemistry 1978, 24: 1940–1947.

    PubMed  Google Scholar 

  12. Kubo, H., Kinoshita, T.: Microdetermination of gentamicin in serum by high pressure liquid chromatography. Journal of Chromatography 1982, 227: 244–248.

    PubMed  Google Scholar 

  13. Peng, G. W., Gadalla, M. A. F., Peng, A., Smith, V., Chiou, W. L.: High-pressure liquid-chromatographic method for determination of gentamicin in plasma. Clinical Chemistry 1977, 23: 1838–1844.

    PubMed  Google Scholar 

  14. Delaney, C. J., Opheim, K. E., Smith, A. L., Plorde, J. J.: Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin. Antimicrobial Agents and Chemotherapy 1982, 21: 19–25.

    PubMed  Google Scholar 

  15. Bäck, S. E., Nilsson-Ehle, I., Nilsson-Ehle, P.: Chemical assay, involving liquid chromatography, for aminoglycoside antibiotics in serum. Clinical Chemistry 1979, 25: 1222–1225.

    PubMed  Google Scholar 

  16. Larsen, N. E., Marinelli, K., Heilesen, A. M.: Determination of gentamicin in serum using liquid column chromatography. Journal of Chromatography 1980, 221: 182–187.

    PubMed  Google Scholar 

  17. Carlson, L. G., Delaney, C. J., Plorde, J. J.: Potential liabilities of gentamicin homogeneous enzyme immunoassay. Antimicrobial Agents and Chemotherapy 1982, 21: 192–194.

    PubMed  Google Scholar 

  18. Selepak, S. T., Witebsky, F. G., Robertson, E. A., MacLowry, J. D.: Evaluation of five gentamicin assay procedures for clinical microbiology laboratories. Journal of Clinical Microbiology 1981, 13: 742–749.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Essers, L. Comparison of a simplified liquid chromatographic assay of gentamicin in serum with enzyme immunoassay and bioassay. Eur. J, Clin. Microbiol. 1, 367–370 (1982). https://doi.org/10.1007/BF02019936

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02019936

Keywords

Navigation