Skip to main content
Log in

Evaluation of a commercially available semi-automated bioluminescence system for bacteriuria screening

  • Original Articles
  • Published:
European Journal of Clinical Microbiology Aims and scope Submit manuscript

Abstract

A commercially available semi-automated bioluminescence adenosine triphosphate assay system for rapid detection of significant bacteriuria was evaluated. Excellent reproducibility of results using the bioluminescence apparatus was noted, and there was no bacterial carry-over using a pre-diluter. The results obtained with 2,000 urine specimens tested by bioluminescence and a routine cultural technique were compared. The bioluminescence system gave no false negative results and a bioluminescence positive/culture negative finding of 13.6 % in general specimens and 45.0 % in ante-natal and maternity specimens. In the latter group, the majority of urines yielded growth of lactobacilli and/or diphtheroids (< 104 organisms/ml) when subcultured on enriched media. Results indicated that bioluminescence may identify urinary tract infections in patients receiving antimicrobial therapy. The advantages of this 45 minute technique for bacteriuria screening are presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Nicholson, D. P., Keopke, J. A.: The Automicrobic system for urines. Journal of Clinical Microbiology 1979, 10: 823–833.

    PubMed  Google Scholar 

  2. Bascomb, S.: Application of automation to the general and specific detection of bacteria. Laboratory Practice 1981, 30: 461–464.

    Google Scholar 

  3. Jenkins, R. D., Hale, D. C., Matsen, J. M.: Rapid semi-automated screening and processing of urine specimens. Journal of Clinical Microbiology 1980, 11: 220–225.

    PubMed  Google Scholar 

  4. Human, R. P., Rowe, G. D.: Automated screening for bacteriuria. Medical Laboratory Sciences 1978, 35: 223–226.

    PubMed  Google Scholar 

  5. Alexander, M. K., Khan, M. S., Dow, C. S.: Rapid screening for bacteriuria using a particle counter, pulse-height analyser and computer. Journal of Clinical Pathology 1981, 34: 194–198.

    PubMed  Google Scholar 

  6. Johnston, H. H., Mitchell, C. J., Curtis, G. D. W.: An automated test for the detection of significant bacteriuria. Lancet 1976, ii: 400–402.

    Google Scholar 

  7. Conn, R. B., Charache, P., Chappelle, E. W.: Limits of applicability of the firefly luminescence ATP assay for the detection of bacteria in clinical specimens. American Journal of Clinical Pathology 1975, 63: 493–501.

    PubMed  Google Scholar 

  8. Thore, A., Ansehn, S., Lundin, A., Bergman, S.: Detection of bacteriuria by luciferase assay of adenosine triphosphate. Journal of Clinical Microbiology 1975, 1: 1–8.

    PubMed  Google Scholar 

  9. Alexander, D. N., Ederer, G. M., Matsen, J. M.: Evaluation of adenosine 5-triphosphate assay as a screening method to detect significant bacteriuria. Journal of Clinical Microbiology 1976, 3: 42–46.

    PubMed  Google Scholar 

  10. Curtis, G. D. W., Johnston, H. H.: A rapid screening test for bacteriuria. In: Schram, E., Stanley, P. E. (ed.): Proceedings of an international symposium on analytical applications of bioluminescence and chemiluminescence. State Printing Publishing Inc., Westlake Village/CA, 1978, p. 448–457.

    Google Scholar 

  11. Kellogg, D. S., Peacock, W. L., Deacon, W. E., Brown, L., Pirkle, C. I.:Neisseria gonorrhoea. 1. Virulence genetically linked to clonal variation. Journal of Bacteriology 1963, 85: 1274–1279.

    PubMed  Google Scholar 

  12. Kass, E. H.: Bacteriuria and the diagnosis of infections of the urinary tract. Archives of Internal Medicine 1957, 100: 709–714.

    Google Scholar 

  13. Mackett, D., Kessock-Philip, S., Bascomb, S., Easmon, C. S. F.: Evaluation of the Lumac kit for the detection of bacteriuria by bioluminescence. Journal of Clinical Pathology 1982. 35: 107–110.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

McWalter, P.W., Sharp, C.A. Evaluation of a commercially available semi-automated bioluminescence system for bacteriuria screening. Eur. J, Clin. Microbiol. 1, 223–227 (1982). https://doi.org/10.1007/BF02019712

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02019712

Keywords

Navigation